background image

B08-590

 • B75 • 09/22 • GB • p. 10 of 20 • www.armano-messtechnik.com

Operating Instructions

PAXd – Display

5.4 Simulation

(only if write protection is disabled)

The PAXd allows you to simulate process values in the simulation menu. By using the optical buttons 

 and 

2

the simulated value can be increased or decreased (

 chapter 2 “Using the Optical Buttons”). Please note that the 

display will not time out while performing a calibration.

Sensor 2

Simulation

Txt 57

Sensor 1

Sensor 2 

*5

CJC Sensor

Average 

*5

Differential 

*5

Loop Curr 

*26

 2

20.0

S2 Simul

Txt 59

-200.0

850.0

 2

20.0

Avg Simul

Txt 61

-200.0

850.0

 2

3

20.00

Loop Test

Txt 63

3.5 mA

23.0 mA

 2

20.0

S1 Simul

Txt 58

-200.0

850.0

 2

20.0

CJC Simul

Txt 60

-40.0

135.0

 2

20.0

Diff Simul

Txt 62

-200.0

850.0

 2

3

3

3

3

3

3

32 

7501V111-UK

Simulation

(only if Write-protection is disabled)

The 7501 allows you to simulate process values by entering the simulation menu. Using the 

 and 

2

 optical buttons, the 

simulated value can be increased and decreased (see the section 

Operating the optical buttons

). Please note that while 

performing a calibration the display will not time out.

Only shown if dual sensor function is 

selected.

*5

Not available in 
HART 5 mode

*26

Not possible if Loop Current is not active.

Sensor 2

Average

Sensor 1

CJC sensor

Differential

Loop Test

“Monitor”

“Monitor”

“Monitor”

“Monitor”

“Monitor”

“Monitor”

 Only shown if dual sensor function is selected.

 Not possible if loop current is not active.

Not available in 

HART 5 mode

Содержание PAXd

Страница 1: ...pplier or contact us directly at ARMANO Messtechnik GmbH Location Beierfeld Am Gewerbepark 9 08344 Gr nhain Beierfeld Tel 49 3774 58 0 Fax 49 3774 58 545 mail armano beierfeld com Location Wesel Manom...

Страница 2: ...he selected parameter unless the device is write protected 2 in monitoring view switch to the previous process variable other display view decrease the value of the selected parameter unless the devic...

Страница 3: ...ter is indicated at the top of the display the currently selected value right below The value can be changed by pressing the opti cal buttons or 2 If applicable information on per missible range and c...

Страница 4: ...r 2 Using the Optical Buttons The display menu is divided into two sections basic configuration and advanced configu ration The advanced configuration is separated into nine sections display tags cali...

Страница 5: ...other menu Warning state will be forced into this state if sensor error or overrange is present Only from Monitor menu 18 Only shown if change of protocol is possible 24 First long press of and 2 simu...

Страница 6: ...Ext Pt100 CJC Type Txt 10 Internal Ext Pt100 Ext Ni100 Fixed 2 2 0 CJC Wire Res Txt 8 100 0 0 0 2 3 Pt Ni TC 3 3 3 3 3 3 3 3 3 5 4 Ohm Res Type Txt 5 Ohm kOhm 2 3 mV Voltage Type Txt 5 uV mV V 2 3 28...

Страница 7: ...selected 8 Only shown if sensor breakage detection is activated Only shown if average sensor function is selected 7 Only shown if sensor shortage detection is activated 9 Only shown if dual sensor fu...

Страница 8: ...color Txt 73 Off White Red 3 Contrast Txt 43 0 9 2 2 2 Range Bar graph Txt 44 Loop Curr Range Sensor 2 Monitor Txt 45 Sensor 1 Sensor 2 5 CJC Sensor Average 7 Differential 6 Loop Curr Range 2 2 3 25 Y...

Страница 9: ...S1 High Txt 75 27 100 0 S1 Cal High Txt 56 200 C 850 C 2 14 Set CJC High Txt 75 27 100 0 CJC Cal Hi Txt 56 40 0 135 0 2 14 26 7501V111 UK 31 Calibration only if Write protection is disabled The devic...

Страница 10: ...A 2 20 0 S1 Simul Txt 58 200 0 850 0 2 20 0 CJC Simul Txt 60 40 0 135 0 2 20 0 Diff Simul Txt 62 200 0 850 0 2 3 3 3 3 3 3 32 7501V111 UK Simulation only if Write protection is disabled The 7501 allow...

Страница 11: ...Menu these changes will be overwritten mV PV Unit Txt 5 All units mV S1 Unit Txt 5 All units 2 2 mV S2 Unit Txt 5 All units F CJC Unit Txt 5 C F K R Yes Save Txt 16 2 2 mV Avg Unit Txt 5 All units mV...

Страница 12: ...thorized modifications to the configuration The device is delivered default with write protection disabled The password 00002008 always allows access to the write protection menu Language In this menu...

Страница 13: ...a Italiano Espa ol 2 3 Yes No 2 15 Yes Save Txt 16 HART 7 HART Rev Txt 51 3 HART 7 HART 5 2 24 Yes No 2 15 34 7501V111 UK HART Revision Changing the HART revision is done from this menu Select the des...

Страница 14: ...QV assign sensor 2 to QV assign CJC sensor to QV assign internal temperature to QV assign average measurement to QV assign differential measurement to QV 21 set the lower value at the analogue output...

Страница 15: ...or type select TC K as sensor type select TC L as sensor type select TC N as sensor type select TC R as sensor type select TC S as sensor type select TC T as sensor type select TC U as sensor type sel...

Страница 16: ...22 mbar 19 9 23 g cm2 20 11 24 Pa 174 25 hPa 21 12 26 kPa 22 13 27 torr 23 14 28 atm 24 237 29 MPa 25 17 32 l min volume flow units 131 35 m3 min 26 19 36 m3 h 27 22 38 gal s 16 39 gal min 28 24 31 l...

Страница 17: ...92 147 109 g m3 93 54 110 cSt viscosity units 94 55 111 cP 95 69 112 N m energy work units 113 Wh 96 128 114 kW h 115 MWh 97 162 116 Mcal 117 kJ 98 164 118 MJ 99 165 119 Btu Sensor menu HART Display...

Страница 18: ...ile Product Input Output C ommunication Language Option 08 30 00 PRetop 5331 Date 1994 8 10 943201594 PRelectronics Analog input Analog output Serial no Inputtype Outputtype 4 20mA Upscale Sensor erro...

Страница 19: ...HART 7 or 15 HART 5 If two devices are con figured with the same address both will be excluded The device must be configured for the multidrop mode with a fixed output signal of 4 mA The maximum cur...

Страница 20: ...V QV Variables in the HART protocol PV Primary Value 4 20 mA SV Secondary Value TV Tertiary Value QV Quaternary Value CJC Cold Junction Compensation TC Thermocouple WTH Resistance Thermometer 2022 ARM...

Отзывы: