www.armano-messtechnik.com • p. 3 of 20 • GB • 09/22 • B75 • 

B08-590

Operating Instructions

PAXd – Display

Meaning of the symbols

The toolbar provides information on the status of the 

device. Information such as HART communication, 

write protection and process value tendency are indi-

cated.

 

   saving the configuration to internal memory

   device is locked or write-protected

   current process value tendency indicators

 

   external HART communication indicator

   internal communication indicator

 

    external HART communication error

 

Monitoring view

The process value in the configured units can be easily 

monitored through the glass of the case. A bargraph 

indicates the process variable at a glance. The device 

tag is indicated at the top of the display. The device tag 

allows easy identification of the process value and can 

be changed by pressing the optical buttons 

 or 

2

. At 

the bottom of the display, the symbols show informa-

tion on the current status of the device.

monitoring view

indicated 

process 

value

process 

value

bargraph

device tag

process 

value unit

symbols

Programming view

Press and hold the optical buttons 

 or 

2

 to access 

the programming view. The programming view guides 

you quickly and intuitively through the device setup. 

The name of the selected parameter is indicated at the 

top of the display, the currently selected value right 

below. The value can be changed by pressing the opti-

cal buttons 

 or 

2

. If applicable, information on per-

missible range and currently configured units are also 

indicated. At the bottom, a scrolling help text shows 

information on the parameter you are modifying.

programming view

minimum 

value

maximum 

value

menu name

actual value

scrolling 

help text

Diagnostics view

The display can be configured to flash with red or 

white background lighting when a sensor or device 

error occurs. The display indicates the status / error 

type in large letters and a scrolling help text with fur-

ther information appears. The device tag is indicated 

at the top of the display and the toolbar at the bottom 

indicates the status of the device. For a detailed de-

scription of the different types of displayed diagnostic 

messages, please refer to chapter 4 “Device and Sen-

sor Status Indication”.

diagnostics view

scrolling 

help text

flashing 

error type 

indication

device tag

symbols

Configuration

During configuration of the PAXd, you are guided 

through all parameters and can select those settings 

that are applicable to your application. For each menu, 

there is a scrolling help text that automatically appears 

in the display. The configuration is carried out via three 

optical buttons. When the configuration is complete or 

the display time has expired, the display returns to the 

monitoring view.

Содержание PAXd

Страница 1: ...pplier or contact us directly at ARMANO Messtechnik GmbH Location Beierfeld Am Gewerbepark 9 08344 Gr nhain Beierfeld Tel 49 3774 58 0 Fax 49 3774 58 545 mail armano beierfeld com Location Wesel Manom...

Страница 2: ...he selected parameter unless the device is write protected 2 in monitoring view switch to the previous process variable other display view decrease the value of the selected parameter unless the devic...

Страница 3: ...ter is indicated at the top of the display the currently selected value right below The value can be changed by pressing the opti cal buttons or 2 If applicable information on per missible range and c...

Страница 4: ...r 2 Using the Optical Buttons The display menu is divided into two sections basic configuration and advanced configu ration The advanced configuration is separated into nine sections display tags cali...

Страница 5: ...other menu Warning state will be forced into this state if sensor error or overrange is present Only from Monitor menu 18 Only shown if change of protocol is possible 24 First long press of and 2 simu...

Страница 6: ...Ext Pt100 CJC Type Txt 10 Internal Ext Pt100 Ext Ni100 Fixed 2 2 0 CJC Wire Res Txt 8 100 0 0 0 2 3 Pt Ni TC 3 3 3 3 3 3 3 3 3 5 4 Ohm Res Type Txt 5 Ohm kOhm 2 3 mV Voltage Type Txt 5 uV mV V 2 3 28...

Страница 7: ...selected 8 Only shown if sensor breakage detection is activated Only shown if average sensor function is selected 7 Only shown if sensor shortage detection is activated 9 Only shown if dual sensor fu...

Страница 8: ...color Txt 73 Off White Red 3 Contrast Txt 43 0 9 2 2 2 Range Bar graph Txt 44 Loop Curr Range Sensor 2 Monitor Txt 45 Sensor 1 Sensor 2 5 CJC Sensor Average 7 Differential 6 Loop Curr Range 2 2 3 25 Y...

Страница 9: ...S1 High Txt 75 27 100 0 S1 Cal High Txt 56 200 C 850 C 2 14 Set CJC High Txt 75 27 100 0 CJC Cal Hi Txt 56 40 0 135 0 2 14 26 7501V111 UK 31 Calibration only if Write protection is disabled The devic...

Страница 10: ...A 2 20 0 S1 Simul Txt 58 200 0 850 0 2 20 0 CJC Simul Txt 60 40 0 135 0 2 20 0 Diff Simul Txt 62 200 0 850 0 2 3 3 3 3 3 3 32 7501V111 UK Simulation only if Write protection is disabled The 7501 allow...

Страница 11: ...Menu these changes will be overwritten mV PV Unit Txt 5 All units mV S1 Unit Txt 5 All units 2 2 mV S2 Unit Txt 5 All units F CJC Unit Txt 5 C F K R Yes Save Txt 16 2 2 mV Avg Unit Txt 5 All units mV...

Страница 12: ...thorized modifications to the configuration The device is delivered default with write protection disabled The password 00002008 always allows access to the write protection menu Language In this menu...

Страница 13: ...a Italiano Espa ol 2 3 Yes No 2 15 Yes Save Txt 16 HART 7 HART Rev Txt 51 3 HART 7 HART 5 2 24 Yes No 2 15 34 7501V111 UK HART Revision Changing the HART revision is done from this menu Select the des...

Страница 14: ...QV assign sensor 2 to QV assign CJC sensor to QV assign internal temperature to QV assign average measurement to QV assign differential measurement to QV 21 set the lower value at the analogue output...

Страница 15: ...or type select TC K as sensor type select TC L as sensor type select TC N as sensor type select TC R as sensor type select TC S as sensor type select TC T as sensor type select TC U as sensor type sel...

Страница 16: ...22 mbar 19 9 23 g cm2 20 11 24 Pa 174 25 hPa 21 12 26 kPa 22 13 27 torr 23 14 28 atm 24 237 29 MPa 25 17 32 l min volume flow units 131 35 m3 min 26 19 36 m3 h 27 22 38 gal s 16 39 gal min 28 24 31 l...

Страница 17: ...92 147 109 g m3 93 54 110 cSt viscosity units 94 55 111 cP 95 69 112 N m energy work units 113 Wh 96 128 114 kW h 115 MWh 97 162 116 Mcal 117 kJ 98 164 118 MJ 99 165 119 Btu Sensor menu HART Display...

Страница 18: ...ile Product Input Output C ommunication Language Option 08 30 00 PRetop 5331 Date 1994 8 10 943201594 PRelectronics Analog input Analog output Serial no Inputtype Outputtype 4 20mA Upscale Sensor erro...

Страница 19: ...HART 7 or 15 HART 5 If two devices are con figured with the same address both will be excluded The device must be configured for the multidrop mode with a fixed output signal of 4 mA The maximum cur...

Страница 20: ...V QV Variables in the HART protocol PV Primary Value 4 20 mA SV Secondary Value TV Tertiary Value QV Quaternary Value CJC Cold Junction Compensation TC Thermocouple WTH Resistance Thermometer 2022 ARM...

Отзывы: