MAGE1 User Guide
21
V1.5 12-1-2022
9.14. User settings
To
enter this section, it is necessary to enter the User Password “1111”.
Modbus
register
Modbus
address
No. of
bytes
Data
type
No. of
decimal
Min
Value
Max Value
Default
Description
Read/
Write
2000
1999
4
Bool
-
0
1
0
Measurement,
0=Stop,
1=Running
R/W
2002
2001
4
Bool
-
0
1
1
Air Detector,
0=OFF,
1=ON
R/W
2004
2003
4
Longint
3
0
999
188
Air Constant
R/W
2006
2005
4
Longint
0
1
30
3
Samples per
Avg.
R/W
2008
2007
4
Longint
-
0
5
3
Low Flow
Cutoff, 0=OFF,
1=0.5%,
2=1%,
3=2%,
4=5%,
5=10%
R/W
2010
2009
4
Bool
-,0
0
1
0
Invert Flow,
0=No-invert,
1=Invert
R/W
2012
2011
4
Longint
0
0
0x29991231
-
Date Settings
R/W
2014
2013
4
Longint
0
0
0x00235959
-
Time Settings
R/W
2016
2015
4
Longint
0
1
247
1
Modbus Slave
Address
R/W
2018
2017
4
Longint -
0
5
0
Modbus
BaudRate,
0=9600,
1=14400,
2=19200,
3=38400,
4=57600,
5=115200
R/W
2020
2019
4
Longint
-
0
3
0
Modbus Parity,
0=Even, 1
stopbit,
1=Odd, 1
stopbit,
2=None, 2
stopbits,
3=None, 1
stopbit
R/W
2022
2021
4
Longint
-
-
-
0
Reserved
-
2024
2023
4
----
-
-
-
0
Always ON
0= OFF,
1= ON
R/W
2026
2025
4
----
3
0
36000
0
Flow Min
R/W
2028
2027
4
----
---
----
---
-
Flow Max
R/W
2030
2029
4
----
0
4
20
4
Current Min
R/W
2032
2031
4
----
---
----
---
20
Current Max
R/W
2034
2033
4
Longint
0
0
13
0
Datalogger
Interval
0= OFF
1= 15 s
2= 30 s
3= 1 min
4= 2 min
5= 5 min
6= 10 min
R/W