CS175-275-575-875 Installation Guide
159
Two-call answering
machine defeat
If enabled, two telephone calls must be made to the premises to defeat an
answering machine. On the first call, let the phone ring one or two times. The
control panel detects these rings and starts a 45-second timer, during which
the control panel answers the next call on the first ring. This is not
recommended for commercial applications.
See
Location 32
on page 64 for more information.
Walktest mode
This is used to verify that all zone inputs operate correctly. Each zone is
triggered and the internal sounder rings.
All activations and restorations of zone inputs during a walktest are logged.
If enabled, entering Chime followed by a user code allows a walk-through
zone test where all zones become silent and local (non-reporting). The
number of the faulted zone(s) is displayed on the LCD keypad. It is also
entered into alarm memory and the internal log. To exit at any time during this
mode, enter a user code. Otherwise the walktest mode automatically exits
after 15 minutes.
See
Location 53
on page 71 for more information.
Wireless sensor
missing/Low battery
The CSx75 sends a report to the central station when a wireless sensor has
detected a low battery or has not reported to the receiver.
See
Location 51
on page 70 for more information.
Zone
An area guarded by a group of one or more detection devices.
Zone activity monitor
This feature sends a report to the central station when a particular zone does
not change conditions within the specified number of days programmed.
See
Location 52
on page 71 and
Location 127
to
Location 206
, starting on
page 80, for more information.
Zone bypassed sounder
alert-
If this feature is enabled, the CSx75 beeps the keypad sounder upon arming if
a zone is bypassed.
See
Location 34
on page 65 for more information.
Zone types
(Configurations)
The CSx75 has 20 programmable zone types that determine how each zone
functions and reports.
See
Location 36
on page 67 for more information.