64
CS175-275-575-875 Installation Guide
Tone dialling
pager or Siren Tone formats. The factory default is
8.
Location 27
Reserved
Location 28
Dialler abort delay (one segment, ND)
This location contains the length of time before the duration of the dialler abort delay
function. The delay can be from 0 to 255 seconds. 0 = no abort delay.
Location 29
Listen-in time (one segment, ND)
This location contains the duration of the listen-in timer. This can be from 0 to 255
seconds. 0= no listen-in time.
Location 30
Download access code (eight segments, ND)
This location contains the eight-digit access code the CSx75 must receive from the
downloading software before the panel permits downloading to occur. The factory default
code is 12780000.
Location 31
Number of rings to answer (one segment, ND)
This location contains the number of rings to answer for a download. Enter a number from
0 (disabled) to 15. The factory default is 8.
This means
the CSx75 answers on eight rings.
Location 32
Download control (one segment, FSD)
This contains the feature selections for controlling download sessions. The following
features can be enabled or disabled using this option.
Segment 1
1
On: enables two-call answering machine defeat. It works by starting a
45-second timer after it sees a one or two-ring call. During this time it
answers on the first ring.
2
Reserved
3
On: requires call back before download session.
4
Shutdown. This can only be viewed from the keypad and must be
changed through downloading.
5
On: locks all local programming. This can only be viewed from the
keypad and must be changed through downloading.
6
On: locks programming of all options associated with the
communicator. This can only be viewed from the keypad and must be
changed through downloading.
7
On: locks out download section. This can only be viewed from the
keypad and must be changed through downloading.
If this is on, Locations 19 to 22 cannot be viewed from the keypad.
8
On: allows an autotest to be interrupted.