152
CS175-275-575-875 Installation Guide
27 G
LOSSARY
24-hour zone
This zone remains armed the whole time unless inhibited by forced arming. It
reports as a normal burglary zone when armed.
“A” and “B” Alarm
Reporting
If a zone is defined as an A zone, an alarm is reported if a zone is activated.
If a zone is defined as a B zone, a second activation must take place within a
pre-set time. Fire and medical and personal attack zones are always treated
as A zones.
See
Location 52
on page 71 and
Location 127
to
Location 206
, starting on
page 80, for more information.
Abort
If enabled, the CSx75 waits the number of seconds programmed in location
52 prior to sending an alarm. To cancel the report, type in a code. Dialer Delay
must be enabled in the Characteristic Select of locations 127 - 206.
See
Location 52
on page 71 and
Location 127
to
Location 206
, starting on
page 80, for more information.
Mains Fail / Low Battery
Report/Warning
The CSx75 can be programmed to report mains failure and/or low battery
conditions to the central station. It can also be programmed to sound the
keypad immediately upon detection of the condition. The mains failure
report/warning can be delayed.
See
Location 51
on page 70 and
Location 52
on page 71 for more information.
Mains Power / Low
Battery Sounder Alert-
If enabled, the CSx75 beeps the keypad sounder upon arming or disarming if
the mains power is missing or a low battery has been detected.
See
Location 34
on page 65 for more information)
Access zone
This is similar to a burglary zone except that activations on these zones are
ignored during entry and exit times.
Account code
The code by which the ARC/central station identifies and charges the user.
ARC (alarm report
centre)
This is the place contacted via telephone when an alarm takes place. It is also
known as a control station or a central station.
Arm / Disarm Codes
The CSx75 can have four-digit codes or six-digit codes to arm/disarm the
control. All codes must have the same number of digits. The factory default for
User #1 is 1122 when using a four-digit code, or 112256
for a six-digit code.
This code can then be used to enter the new arm/disarm codes.
See
Location 53
on page 71 for more information.
Armed
The security system is on.
Autotest
This feature causes the panel to call the central station to report a
communicator test at a specified interval.
See
Location 63
and
Location 64
on page 75 for more information.