covers shall be continuously monitored by the intruder 
detection system to detect unauthorised opening.  

It is recognised that not all enclosures have the provision to 
accept conduit. Where this is the case, screened cable may be 
installed between the conduit terminating box and the 
equipment. The exposed screen shall be kept as short as 
possible at the point of entry into enclosures and shall be 
terminated at one end to a cross bonded main earth point. 

Wiring associated with alarm transmission paths (ATPs) shall 
be concealed as far as is practical and means provided to 
prevent the inadvertent disconnection of plug-in transmission 
connections (for example, telephone socket with a locking 
facility). When ordering a dedicated connection for the 
supervised premises transceiver (SPT) from a 
telecommunications provider, it is recommended that in 
addition to the telephone socket outlet, a ‘block terminal’ is 
fitted adjacent to the enclosure containing the SPT for 
diagnostic purposes. 

Where the routing of ATP wiring may be exposed to potential 
lightning strikes, consideration should be given to the use of 
additional lightning protection devices. Many SPT devices have 
electrical transient suppression fitted which often requires the 
SPT to have an electrical earth connection. Confirmation 
should be sought from the alarm company that the earth 
connection has been made correctly to a known good earth 
potential. Failure to do so will result in the non-operation of the 
transient protection device and a very high probability of a 
catastrophic failure of the SPT.  

Any landline-based alarm transmission path (Ethernet, PSTN, 
etc.) shall have a cable interconnection between the SPT and 
the first suitable alarm transmission network termination point 
within the premises. This interconnection shall be made in one 
continuous run and use termination components (or housings) 
that protect against cable removal without the use of a tool. 
The connection to the alarm transmission network shall be 
made in such a manner that where non-alarm related 
apparatus/services are also connected to that network, they do 
not prevent, or interfere with, the correct operation of the alarm 
transmission system. 

INCERT policy 

The required settings for INCERT Grade 2 are all EN 50131 
Grade 2 required settings, and settings for INCERT Grade 3 
are all EN 50131 Grade 3 required settings, with the following 
modifications: 

• 

1.2.9.1.m.n.2 Batt.test freq: Everyday 

• 

8.2.1 User code required: Enabled 

• 

8.3.3 Alarm list: Disabled 

• 

8.4.1 RTS options: FTC and Battery fault set to On 

• 

8.4.2 Inhibit includes: Battery fault must be set to Access 
level 2 

• 

8.4.6 Pending alarms: Enable EN 50131 

• 

9.3.n.2 Line fault: Set to If used or On 

• 

9.3.n.7.7 Line fault: Set to On 

See also “EN 50131 Grade 2” on page 12 and “EN 50131 
Grade 3

” on page 13. 

For INCERT T031 installations the following devices should be 
mounted in metal housings only: ATS7700, ATS7200E, 
RC213, ATS1810, ATS1811, ATS1202, ATS1330, ATS1740, 
ATS1743. 

SES policy 

Depending on the SES default chosen, the following SES 
settings are required on top of EN 50131 Grade 2 / Grade 3. 

• 

Take care that a proper dedicated panic button is used 
(which cannot be pushed by accident). 

• 

Automatic unsetting is not allowed. 

• 

For SES Grade 3 is not allowed to program GPRS 
communication as primary CS, it is only allowed in 
Grade 2. 

• 

The table below indicates the required polling intervals for 
SES Grade 2 and Grade 3. 

 

 

 

 

Primary CS (IP) 

 

 

 

AÜA-
B25 

AÜA-
B5 

AÜA-
S180 

AÜA-
S20 

 

 

 

25 h 

5 h 

180 s  20 s 

Back-up CS 
(GPRS) 

AÜA-B25  25 h 

2, 3 

2, 3 

2, 3 

AÜA-B5 

5 h 

2, 3 

2, 3 

2, 3 

* 2, 3: EN-CH Grade of the system 

• 

The following options must be set: 

 

Standard 
and 
category 

Required 
polling 
interval 

Comm. path 
and dialler 

Option 

Required 
value 

SES CHD.07 (V3 / 01.01.2011)

 

 

 

AÜA-B25 

25 h 

IP built-in, or 
GPRS via 
ATS73X0 

Heartbeat 
time 

24 

AÜA-B5 

5 h 

IP built-in, or 
GPRS via 
ATS73X0 

Heartbeat 
time 

AÜA-S180  180 s 

IP built-in, or 
GPRS via 
ATS73X0 

Heartbeat 
time 

00:02'30 

AÜA-S20 

20 s 

IP built-in 

Heartbeat 
time 

00:00'10 

SBSC policy 

Larmklass 1 

Required settings are all EN 50131 Grade 2 settings with the 
following modifications: 

• 

4.2.n.5.1 Entry alarms: Instant 

• 

8.7.6.9 Reporting delayed: No 

See also “EN 50131 Grade 2” on page 12. 

Larmklass 2 

Required settings are all EN 50131 Grade 3 settings with the 
following modifications: 

• 

4.2.n.5.1 Entry alarms: Instant 

• 

8.7.6.9 Reporting delayed: No 

See also “EN 50131 Grade 3” on page 13. 

Содержание ATS 500A Series

Страница 1: ...T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0V D D 250 250 9 30 61 5 28 2 37 2 125 9 61 5 126 4 118 Ø20 2 1 1 1 1 1 Rx Tx USB MI IP CON12 CON13 T1 T2 S4 S5 S1 C S2 C T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0VD D 315 40 385 55 1 1 1 1 1 1 15 109 4 102 5 60 2 60...

Страница 2: ... C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0V D D 259 129 5 73 403 54 5 45 5 73 395 50 5 70 126 5 41 5 70 253 1 1 1 2 Rx Tx USB MI IP CON12 CON13 T1 T2 S4 S5 S1 C S2 C T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0VD D 35 315 90 31 33 24 445 35 97 5 157 5 157 5 1 1 1 1 1 2 ...

Страница 3: ...ium MM and MM and large housing LM pry off tamper mount N N Rx Tx USB MI IP CON12 CON13 T1 T2 S4 S5 S1 C S2 C T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0V D D 1 1 1 1 1 2 COM NO COM NO C T TAMPER B C D E A MM MM LM ...

Страница 4: ...shielding B A 1 2 3 5 6 10 9 22 21 23 18 16 24 25 19 17 15 14 26 4 11 13 Rx Tx USB MI IP CON12 CON13 T1 T2 S4 S5 S1 C S2 C T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0V D D 12 20 8 7 1740 ATS1201 E 1740 Advisor Advanced ATS1210 E ATS1135 ATS1203 E 1 2 3 4 5 6 7 3 3 4 4 4 4 5 5 7 7 8 9 8 9 9 ...

Страница 5: ...TS1500A IP MM Metal MM 315 x 388 x 85 5 2 ATS1500A SM Metal SM 250 x 250 x 86 2 8 Model Enclosure Dimensions mm Weight kg ATS1500A IP SM Metal SM 250 x 250 x 86 2 8 ATS1500A LP Plastic LP 257 x 400 x 112 2 6 ATS1500A IP LP Plastic LP 257 x 400 x 112 2 6 ATS3500A MM Metal MM 315 x 388 x 85 5 2 ATS3500A IP MM Metal MM 315 x 388 x 85 5 2 ATS3500A LP Plastic LP 257 x 400 x 112 2 6 ATS3500A IP LP Plast...

Страница 6: ...ons are given in mm For more details on connections and connecting devices to the Advisor Advanced see Cabling on page 8 For details on connecting pry off tampers see Pry off tamper mounting below Pry off tamper mounting For medium MM and MM and large housings LM follow the steps in Figure 6 For large plastic housing LP follow the steps in Figure 7 Caution Once the ATS MM TK tamper assembly has be...

Страница 7: ...at depending on the battery model the connectors can be located differently 5 Mount the battery shield using four screws WARNING The battery shield must be mounted during normal device operation In case a battery BS131 12 V 18 Ah in an ATS1640 housing is used in combination with ATS7700 PSTN expander board it is required to have double insulation in place Use adequately insulated wires for PSTN ca...

Страница 8: ...on may not exceed 30 m For longer distances use relay output expansion for example ATS624 four relay expander The minimum clearance between equipment closures is 50 mm between equipment vents Only use these units in a clean environment and not in humid air Environmental requirements are given in Specifications on page 9 For the panel terminal connections the recommended torque is 0 3 to 0 4 N m Th...

Страница 9: ...e zones However by programming the zones as dual loop all zone inputs can be programmed to give a few states indication for the same zone Depending on the detector model do the following to set up zones Choose your EOL connection type Program input mode Set end of line resistor values Configure anti masking option Refer to Advisor Advanced ATSx500A Installation and Programming Manual for details S...

Страница 10: ...ngs applicable for particular batteries are specified in Auxiliary current and battery capacity on page 11 6 High temperature and multiple charge cycles may greatly reduce battery life time See the specifications for your battery for more information 7 If during a manual or a programmed battery test the battery voltage drops below this threshold the battery test fails 8 Deep discharge protection m...

Страница 11: ...de or minimum air pressure 2000 m above mean sea level Fuses Battery ATS1500A IP ATS3500A IP 2 A resettable ATS4500A IP 3 A resettable 12 V aux 1 A resettable System databus 1 A resettable Siren 1 high current output S1 1 A resettable Siren 2 high current output S2 1 A resettable Siren 3 high current output S3 1 A resettable Mains mains fuse ATS1500A IP SM LP T 160 mA 230 VAC slow Aritech 33 119 A...

Страница 12: ...attery charger fail Fuse power output fail Output overload Monitoring function Message Cause Power outputs Fuse power output fail Exhausted fuse Fuse loss Short circuit Overload Power supply Power unit power output fail Power unit failure Overvoltage Tampers Device tamper Device sabotage 1 Mains fail and Battery low will finally result in Battery deep discharge protection 2 Mains fault message is ...

Страница 13: ...rmed daily The following features are not allowed not evaluated Keyswitch zone types to set and unset the system Presetting indication and any automatic override of set prevention Refer to Table 6 below for all supported options for notification requirements Table 6 EN 50131 1 2006 options Notification equipment Alarm reporting Grade 3 options A B C D Remotely powered audible WD 2 Optional Optiona...

Страница 14: ...vices depending on intrusion panel regardless of type independent of other expanders ATS1201E 8 to 32 zone DGP expander with 3 A PSU small enclosure EN 50131 Grade 3 ATS1204E 8 to 32 zone DGP expander with 3 A PSU large enclosure EN 50131 Grade 3 I O expanders Panel can support up to 3 I O devices depending on the type ATS608 Plug in 8 zone expander ATS624 4 relay board ATS626 16 open collector ou...

Страница 15: ... ATS1451 ATS1452 ATS1455 ATS1457 ATS1458W ATS1458B ATS1459 ATS1482 Wiring and interconnections when used for CPNI applications The use of wiring and the associated interconnections shall be appropriate for the system performance required and the local conditions within the service environment The installation should conform to good working practices and be in accordance with the requirements of th...

Страница 16: ...re also connected to that network they do not prevent or interfere with the correct operation of the alarm transmission system INCERT policy The required settings for INCERT Grade 2 are all EN 50131 Grade 2 required settings and settings for INCERT Grade 3 are all EN 50131 Grade 3 required settings with the following modifications 1 2 9 1 m n 2 Batt test freq Everyday 8 2 1 User code required Enab...

Страница 17: ...500A IP MM is upgradable to Security Grade 3 using the ATS MM TK tamper kit Mode of operation as per EN 50136 2 2013 The transmission of the events to the central station takes place by means of pass through procedures in accordance with EN 50136 2 2013 Tested and certified by VdS Schadenverhütung GmbH Important To comply with the above standards it is required to configure the system according to...

Страница 18: ...18 18 P N 466 5570 EN REV E ISS 22MAR22 ...

Отзывы: