Aritech ATS 500A Series Скачать руководство пользователя страница 13

 

P/N 466-

5570 (EN) • REV E • ISS 22MAR22 

 

13 / 18 

It is required to apply the following supervision settings for 
wireless DGPs:  

• 

Short supervision: 20 minutes 

• 

Long supervision: 2 hours 

• 

Smoke supervision: 4 hours 

Refer to appropriate sections and manuals. 

Caution: 

When any option, any additional function or any 

additional zone type in this section does not comply with the 
EN 50131 requirements, the EN 50131 Grade 2 label must be 
removed from the system. 

Additional functions 

The Wireless PIR Camera functionality brings along video 
verification feature, this additional function is fully available 
without compromise to standards the system complies to. 

The Wireless PIR camera system consists of the following: 

• 

Advisor Advanced series control panel 

• 

ATS1238 Advanced Wireless DGP  

• 

TX-2344-03-1 Wireless PIR Camera 

• 

ATS73X0 GSM/GPRS Module 

These PIR camera settings have no influence on EN 50131 
compliance: 

• 

2.2.2.n.4.9.1.1.2 Frame rate for all event types 

• 

2.2.2.n.4.9.1.1.3 Pic resolution for all event types 

• 

2.2.2.n.4.9.3 Pic auto deletion 

• 

4.5 Cameras 

• 

9.1.n.4.5 Pic dest port 

• 

9.3.n.11 Max Pics 24h, 9.3.n.7.9 Max Pics 24h 

EN 50131 Grade 3 

The following options and values are mandatory for EN 50131-
1 Grade 3 regulations: 

• 

All Grade 2 

required settings (see “EN 50131 Grade 2” on 

page 12). 

• 

PIN length should be 6 digits minimum. 

• 

3.2.n.6 User group options, set (6) Isolate, (22) SMS 
reporting, (23) SMS control to No for all user groups 
except Installer. 

• 

4.1.n.6.7 Anti mask, set to Yes for all I&HAS movement 
detectors 

• 

4.2.n.2.1 Exit time 1

, ≤ 180 s 

• 

8.1.3.4 Mains reporting delay

, ≤ 1 h 

• 

8.3.5 View EE timer, set to Off 

• 

8.4.1 RTS options, set Zone masking condition to Yes 

• 

8.4.2 Inhibit includes, set Zone masking condition to 
Access Level 2 

• 

Battery test should be performed daily. 

The following features are not allowed (not evaluated): 

• 

Keyswitch zone types to set and unset the system.  

• 

Presetting indication and any automatic override of set 
prevention. 

Refer to Table 6 below for all supported options for notification 
requirements. 

Table 6: EN 50131-1:2006 options 

Notification 
equipment (Alarm 
reporting) 

Grade 3 options  

A   

B   

C   

D   

Remotely powered 
audible WD 

Optional 

Optional 

Optional 

Self-powered audible 
WD 

Optional  

Optional 

Optional 

Main ATS [1] 

ATS 4   

ATS 4   

ATS 4   

ATS 5   

Additional ATS [1] 

Optional  

Optional  

ATS 3   

Optional 

ATS [2] 

SP3 

SP3 

DP3 [3] 

SP4 

[1]  Requirement according to EN 50136:2010 
[2]  Requirement according to EN 50136:2012 
[3]  Primary Path 

— SP4, backup path — SP2 

Legend: 

• 

ATS: Alarm transmission system 

• 

SP: Single path alarm transmission system 

• 

DP: Dual path alarm transmission system 

The key variations of cards and keys are the following: 

• 

ATS147x range (used with ATS1135 and ATS119x): 
67 million 

• 

ATS145x card range (used with ATS1136 and ATS118x): 
280 trillion 

The cards make use of 26 bit (to 48 bit) Hitag protocol. 

The installer (user level 3) commissions the system with 
appropriate additional functions.  

The end-user (user level 2) is able to make use of all these 
functions.  

The Installer can only make use of these functions when he 
has an access granted by end-user. 

EN 50136 policy 

Required settings: 

• 

9.1.n.7 Retry count: 1 

• 

9.1.n.8.3.2 Heartbeat time: According Table 7 on page 14.  

• 

9.1.n.8.3.5 Freq. HB time: According Table 7 on page 14. 

• 

9.3.n.8.1 Firewall: Yes 

• 

9.3.n.8.2 Reply on PING: No 

• 

9.3.n.7.6.1 Firewall: Yes 

• 

9.3.n.7.6.2 Reply on PING: No 

• 

9.3.n.9 Encryption: Yes 

• 

9.4.3 Encryption key 1 must be set. 

See also “Transmitter polling interval requirements” below. 

Transmitter polling interval requirements 

Transmitter polling interval must be set according to specified 
requirements for different alarm transmission systems (ATS). 
Table 7 on page 14 lists all required settings for the 
appropriate standards and diallers. 

Содержание ATS 500A Series

Страница 1: ...T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0V D D 250 250 9 30 61 5 28 2 37 2 125 9 61 5 126 4 118 Ø20 2 1 1 1 1 1 Rx Tx USB MI IP CON12 CON13 T1 T2 S4 S5 S1 C S2 C T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0VD D 315 40 385 55 1 1 1 1 1 1 15 109 4 102 5 60 2 60...

Страница 2: ... C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0V D D 259 129 5 73 403 54 5 45 5 73 395 50 5 70 126 5 41 5 70 253 1 1 1 2 Rx Tx USB MI IP CON12 CON13 T1 T2 S4 S5 S1 C S2 C T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0VD D 35 315 90 31 33 24 445 35 97 5 157 5 157 5 1 1 1 1 1 2 ...

Страница 3: ...ium MM and MM and large housing LM pry off tamper mount N N Rx Tx USB MI IP CON12 CON13 T1 T2 S4 S5 S1 C S2 C T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0V D D 1 1 1 1 1 2 COM NO COM NO C T TAMPER B C D E A MM MM LM ...

Страница 4: ...shielding B A 1 2 3 5 6 10 9 22 21 23 18 16 24 25 19 17 15 14 26 4 11 13 Rx Tx USB MI IP CON12 CON13 T1 T2 S4 S5 S1 C S2 C T C 1 C 2 3 C 4 5 C 6 7 C 8 AC BATT LC OUTPUTS HC OUTPUTS SIR TMP AUX POWER INPUTS C T S3 C CON16 NTC COMMS 12V 0V D D 12 20 8 7 1740 ATS1201 E 1740 Advisor Advanced ATS1210 E ATS1135 ATS1203 E 1 2 3 4 5 6 7 3 3 4 4 4 4 5 5 7 7 8 9 8 9 9 ...

Страница 5: ...TS1500A IP MM Metal MM 315 x 388 x 85 5 2 ATS1500A SM Metal SM 250 x 250 x 86 2 8 Model Enclosure Dimensions mm Weight kg ATS1500A IP SM Metal SM 250 x 250 x 86 2 8 ATS1500A LP Plastic LP 257 x 400 x 112 2 6 ATS1500A IP LP Plastic LP 257 x 400 x 112 2 6 ATS3500A MM Metal MM 315 x 388 x 85 5 2 ATS3500A IP MM Metal MM 315 x 388 x 85 5 2 ATS3500A LP Plastic LP 257 x 400 x 112 2 6 ATS3500A IP LP Plast...

Страница 6: ...ons are given in mm For more details on connections and connecting devices to the Advisor Advanced see Cabling on page 8 For details on connecting pry off tampers see Pry off tamper mounting below Pry off tamper mounting For medium MM and MM and large housings LM follow the steps in Figure 6 For large plastic housing LP follow the steps in Figure 7 Caution Once the ATS MM TK tamper assembly has be...

Страница 7: ...at depending on the battery model the connectors can be located differently 5 Mount the battery shield using four screws WARNING The battery shield must be mounted during normal device operation In case a battery BS131 12 V 18 Ah in an ATS1640 housing is used in combination with ATS7700 PSTN expander board it is required to have double insulation in place Use adequately insulated wires for PSTN ca...

Страница 8: ...on may not exceed 30 m For longer distances use relay output expansion for example ATS624 four relay expander The minimum clearance between equipment closures is 50 mm between equipment vents Only use these units in a clean environment and not in humid air Environmental requirements are given in Specifications on page 9 For the panel terminal connections the recommended torque is 0 3 to 0 4 N m Th...

Страница 9: ...e zones However by programming the zones as dual loop all zone inputs can be programmed to give a few states indication for the same zone Depending on the detector model do the following to set up zones Choose your EOL connection type Program input mode Set end of line resistor values Configure anti masking option Refer to Advisor Advanced ATSx500A Installation and Programming Manual for details S...

Страница 10: ...ngs applicable for particular batteries are specified in Auxiliary current and battery capacity on page 11 6 High temperature and multiple charge cycles may greatly reduce battery life time See the specifications for your battery for more information 7 If during a manual or a programmed battery test the battery voltage drops below this threshold the battery test fails 8 Deep discharge protection m...

Страница 11: ...de or minimum air pressure 2000 m above mean sea level Fuses Battery ATS1500A IP ATS3500A IP 2 A resettable ATS4500A IP 3 A resettable 12 V aux 1 A resettable System databus 1 A resettable Siren 1 high current output S1 1 A resettable Siren 2 high current output S2 1 A resettable Siren 3 high current output S3 1 A resettable Mains mains fuse ATS1500A IP SM LP T 160 mA 230 VAC slow Aritech 33 119 A...

Страница 12: ...attery charger fail Fuse power output fail Output overload Monitoring function Message Cause Power outputs Fuse power output fail Exhausted fuse Fuse loss Short circuit Overload Power supply Power unit power output fail Power unit failure Overvoltage Tampers Device tamper Device sabotage 1 Mains fail and Battery low will finally result in Battery deep discharge protection 2 Mains fault message is ...

Страница 13: ...rmed daily The following features are not allowed not evaluated Keyswitch zone types to set and unset the system Presetting indication and any automatic override of set prevention Refer to Table 6 below for all supported options for notification requirements Table 6 EN 50131 1 2006 options Notification equipment Alarm reporting Grade 3 options A B C D Remotely powered audible WD 2 Optional Optiona...

Страница 14: ...vices depending on intrusion panel regardless of type independent of other expanders ATS1201E 8 to 32 zone DGP expander with 3 A PSU small enclosure EN 50131 Grade 3 ATS1204E 8 to 32 zone DGP expander with 3 A PSU large enclosure EN 50131 Grade 3 I O expanders Panel can support up to 3 I O devices depending on the type ATS608 Plug in 8 zone expander ATS624 4 relay board ATS626 16 open collector ou...

Страница 15: ... ATS1451 ATS1452 ATS1455 ATS1457 ATS1458W ATS1458B ATS1459 ATS1482 Wiring and interconnections when used for CPNI applications The use of wiring and the associated interconnections shall be appropriate for the system performance required and the local conditions within the service environment The installation should conform to good working practices and be in accordance with the requirements of th...

Страница 16: ...re also connected to that network they do not prevent or interfere with the correct operation of the alarm transmission system INCERT policy The required settings for INCERT Grade 2 are all EN 50131 Grade 2 required settings and settings for INCERT Grade 3 are all EN 50131 Grade 3 required settings with the following modifications 1 2 9 1 m n 2 Batt test freq Everyday 8 2 1 User code required Enab...

Страница 17: ...500A IP MM is upgradable to Security Grade 3 using the ATS MM TK tamper kit Mode of operation as per EN 50136 2 2013 The transmission of the events to the central station takes place by means of pass through procedures in accordance with EN 50136 2 2013 Tested and certified by VdS Schadenverhütung GmbH Important To comply with the above standards it is required to configure the system according to...

Страница 18: ...18 18 P N 466 5570 EN REV E ISS 22MAR22 ...