Heat pump water heater – GENERAL INFORMATION
31
2.5 Technical data table
Description
Unit of
measurement
150 L
200 L
300 L
INTERNAL UNIT
Rated tank capacity
l
150
200
300
Insulation thickness
mm
≈ 55
≈ 55
≈ 50
Type of internal tank protection
enamelling
Type of corrosion protection
titanium impressed current anode + disposable magnesium anode
Maximum operating pressure
MPa
0,6
Diameter of hydraulic connections
II
3/4 M
Diameter of gas connections
II
1/4 & 3/8 flare type
Minimum water hardness
°F
12 (with water softener, min 15°F)
Weight when empty
kg
60
65
87
Heating element power
W
1500+1000
1500+1000
1500+1000
Protection rating
IP24
IP24
IP24
Min. temperature of room of
installation
°C
1
1
1
EXTERNAL UNIT
Unit of
measurement
Heat rating (*)
W
2100
Average electrical power
consumption (*)
W
680
Max. electrical power consumption
(*)
W
1000
Refrigerant connection diameter
II
1/4 & 3/8 flare type
Weight when empty
kg
32
Standard air flow rate
m
3
/h
1300
Sound power
dB(A)
60
Level of sound pressure at 5 m
dB(A)
42
Max. pressure of refrigerating
circuit (low-pressure side)
MPa
1.2
Max. pressure of refrigerating
circuit (high-pressure side)
MPa
2.7
Protection rating
IP24
Minimum air temperature (***)
°C
-5
Maximum air temperature (***)
°C
42
Gas connection maximum lenght
m
6
Gas connection maximum drop
m
3
Quantity of R134a refrigerant fluid
g
1300