Heat pump water heater – GENERAL INFORMATION
32
PERFORMANCES
Unit of
measurement
150 L
200 L
300 L
COP (*)
3,1
3,1
3,1
Heating time with heat pump (*)
h:min
3:00
4:00
6:24
Heating energy consumption (*)
kWh
2,0
2,58
4,28
Max. amount of
hot water in a
single intake V
40
(**)
Delivered at 51°C
l
180
260
426
Delivered at 62°C
l
230
318
549
Max. water temperature with heat
pump
°C
62 (55 factory default
setting)
62 (55 factory default
setting)
62 (55 factory default
setting)
Max. water temperature with
heating element
°C
75 (65 factory default
setting)
75 (65 factory default
setting)
75 (65 factory default
setting)
QPr (over 24h)
KWh
0,49
0,52
0,63
Power source
Voltage / max. power consumption
(*)
V / W
220-240 single-phase / 2500
Frequency
Hz
50
Max. current consumption
A
10,8
(*) values obtained with air temperature of 7°C, 87% relative humidity and input water temperature of 15°C (in
conformity with the NF Cahier de Charge
standard).
(**) Performance measured for heating of water between 15°C and 51°C with a temperature for the aspirated air of 15°C and 70%
relative humidity, in compliance with the cahier des charges of the NF Electricitè performance N°LCIE 103-15 mark relative to
independent storage water heaters.
(***) outside of the heat pump’s interval of operation, heating of the water is ensured by the heating element..
Average value obtained on a significant number of products.
Содержание Nuos EVO SPLIT 300
Страница 2: ......
Страница 99: ...97 3 1 2 ...
Страница 100: ...98 4 ...
Страница 101: ...99 5 6 7 8 9 10 ...
Страница 102: ...100 12 300L 150L 200L 11 ...
Страница 103: ...101 15 16 14 13 ...
Страница 104: ...WE MAKE USE OF RECYCLED PAPER Codice 0711 ...