1. Disconnect electrical connections “P” and silicone pipe
“Q” (F
IG
.6.24);
2. Remove screw “R” and remove the fan collar clamp “R”
(F
IG
.6.25);
3. Remove screws “S” (F
IG
.6.26);
4. Remove fan and mounting plate (F
IG
.6.27).
6.3.6 Removing the fan
F
IG
. 6.26
S
S
S
F
IG
. 6.25
R
F
IG
. 6.24
P
P
Q
F
IG
. 6.27
6.4.1. Removing the spark generator
(HONEYWELL Gas Valve)
1. Disconnect ignition leads “T” by pulling upward
(F
IG
. 6.28);
2. Remove the screw “U” (F
IG
. 6.29);
3. Remove the spark generator by pulling forward from
the gas valve (F
IG
. 6.30).
F
IG
. 6.28
F
IG
. 6.29
F
IG
. 6.30
T
U
6.4
A
CCESS TO THE
G
AS
V
ALVE