62
1. Check the fan cable
2. Replace the fan
3. Replace the main P.C.B.
1. Check/replace ignition
electrode
2. Check ignition cable
3. Check/replace the main P.C.B.
Replace
the main P.C.B.
IS THE FAN
RUNNING?
DOES CODE
E33 APPEAR?
IGNITION
SPARKS ARE GENERATED
REGULARLY?
YES
YES
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
1. Check the power supply
of the gas valve.
2. Check for an air
pressure signal
3. Check the gas pressure
on the burner
4. Check the soft-light
adjustment
5. Replace the gas valve
6. Check/replace the
main P.C.B.
1. See section 3.7
2. Press RESET
1. See section 3.7
IS THE BURNER
ALIGHT?
BOILER HAS
SHUTDOWN?
YES
YES
YES
YES
NO
NO
NO
NO
IS
THERE STILL
A PROBLEM?
NORMAL
OPERATION
NO
NO
YES
YES
B
Содержание microGENUS HE 24 MFFI
Страница 20: ...20 Fig 2 22 NOTE DRAWINGS ARE INDICATIVE OF FLUEING OPTIONS ONLY TYPE 1 TYPE 5 TYPE 4 TYPE 3 TYPE 2 FIG 2 21...
Страница 68: ...68 10 BENCHMARK COMMISSIONING CHECKLIST...
Страница 69: ...69 11 SERVICE INTERVAL RECORD...
Страница 70: ...70...
Страница 71: ...71...