47
1. Remove screw “P” (F
IG
.6.24);
2. Disconnect electrical connections “Q” and silicone pipe
“Q1” (F
IG
.6.25);
3. Remove fan and gasket “R” (F
IG
.6.26).
4. Reassemble in reverse order, ensuring the gasket “R”
is seated correctly.
6.3.6 Removing the fan
1. To remove the flue sensor, disconnect electrical
connections “S” (F
IG
.6.27);
2. Remove screws “T” and remove the flue sensor
(F
IG
.6.28 - 6.29).
3. To remove the condensate sensor, remove screws “T1”
and remove the condensate sensor (resistor wire)
(F
IG
.6.27);
6.3.7
Removing the flue sensor and
condensate sensor
F
IG
. 6.24
F
IG
. 6.25
F
IG
. 6.26
R
Q
Q
P
F
IG
. 6.27
F
IG
. 6.28
F
IG
. 6.29
S
T
S1
Q1