settings - adjustment - problem identification menus
menu
sub
-menu
par
amet
er
description
value
default setting
7 TEST & UTILITIES
7 0 0
Function test - Cleaning
turn the encoder to select the operating
mode
t-- = funct. at Max heating
power
t-- = funct. at Max DHW power
t-- = funct. at Min power
t--
activation can also be obtained by pressing the
Reset
button for 10 seconds. The function is deactivated after
10 minutes or by pressing
Esc
7 0 1
Bleed cycle
press
Menu
8 PARAMETER FOR TECHNICAL ASSISTANCE
8 1
Entering access code
turn the encoder clockwise to select 34 and press the
M
enu
button
8 2 BOILER
8 2 0
NOT PRESENT
8 2 1
Fan status
ON or OFF
8 2 2
Fan speed (x100) rpm
8 2 3
Circulation pump speed
OFF - LS - HS
8 2 4
Distribution valve position
Domestic hot water - Heating
8 2 5
Water flow rate (l/min)
8 2 6
NOT PRESENT
8 3 BOILER TEMPERATURE
8 3 0
Heating adjustment temperature (°C)
8 3 1
Heating flow temperature (in °C)
8 3 2
Heating backflow temperature (in °C)
8 3 3
Domestic hot water temperature (in °C)
8 4 SOLAR APPLIANCE AND TANK
8 4 0
Accumulated measured temperature
activated only with the solar kit connected or external
tank
8 4 1
Solar collector temperature
8 4 2
Solar appliance water input temperature
8 4 3
Solar appliance low tank sensor temperature
8 4 4
Layered tank set temperature
8 4 5
Total circulation pump operating time delay for solar appliance
8 4 6
Total solar collector overheating time delay
8 5 SERVICE - TECHNICAL ASSISTANCE
8 5 0
Time remaining before next service
setting
0 to 60 (months)
4 once the parameter is set, the boiler will show the user
the interval before the next service
8 5 1
Service warning authorisation
ON or OFF
OFF once the service has been performed, set the
parameter to clear the warning
8 5 2
Clearing the service warning
Reset
OK = yes
ESC = no
8 5 3
NOT PRESENT
8 5 4
PCB hardware version
8 5 5
PCB software version
8 5 6
PUS peripheral device interface software version