Supplied By www.heating spares.co Tel. 0161 620 6677
59
MAINTENANCE GUIDE
MAINTENANCE GUIDE: GENUS HE
4.3
BURNER
BURNER
Time
15 min
Tools
1
Remove the silencer
Isolate the gas supply. Remove the
four screws and disconnect the
gas pipe from the gas valve
1. Stainless Steel Burner
2. Ignition electrode
3. Detection electrode
Power
Length
Venturi
24 KW
104.6 mm Ø 42 mm
30 KW
135.8 mm
/
38 KW
167 mm
/
Pull the assembly towards
you
2
Remove the three screws to free
the burner door
Pull the burner toward you.
Replace any gaskets that are damaged or showing signs of
deterioration
1
3
2
Page. 20 of 24