Supplied By www.heating spares.co Tel. 0161 620 6677
6
MAINTENANCE GUIDE
MAINTENANCE GUIDE: GENUS HE
5 ANNUAL MAINTENANCE
Plate heat exchanger
Maintenance Interval: As necessary
How: To measure specification of DHW performance.
By-pass & Safety valve
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
Central heating filter
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
Expansion vessel
Maintenance Interval: Annually
How: Check air pressure is at 1 bar (System drained)
Flow switch operation
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
/ Check flow rate
Ignition & detection electrodes
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary / Distance from the burner /
Ionisation current more than 1 µA
Burner
Maintenance Interval: Annually
How: Visual inspection / Clean as necessary
Page. 23 of 24
5. ANNUAL MAINTENANCE