installation
Room thermostat connection
-
Introduce the thermostat wire
- Loosen the cable clamp using a screwdriver and insert the
wires leading from the room thermostat one at a time.
- Connect the wires to the terminals as indicated in the figure
below, removing the link
- Make sure that they are well connected and that they are
not subject to stress when the control panel lid is opened or
closed
- Close the flap again, then replace the control panel cover and
the front casing.
Outdoor sensor connection
-
Introduce the outdoor sensor wires
- Loosen the cable clamp using a screwdriver and insert the
wires leading from the outdoor sensor one at a time.
- Connect the wires to the terminals as indicated in the figure
below;
- Make sure that they are well connected and that they are
not subject to stress when the control panel lid is opened or
closed;
- Close the flap again, then replace the control panel cover and
the front casing.
- Refer to page 39 for setting the parameters when using the
outdoor sensor.
N
ote
:
w
heN
coNNectiNg
the
boiler
to
exterNal
coNtrols
,
do
Not
ruN
240V
cables
aNd
cables
for
switchiNg
circuits
(
which
are
low
Voltage
)
together
,
use
seperate
cables
to
preVeNt
iNduced
Voltage
oN
the
low
Voltage
circuits
.
CARTE CHAUDIERE
AMPC-GAL1
Transmetteur BUS (Optionnel)
Emplacemen
t
car
te optionnelle
SE
TA1
Connector SE on PCB
Outdoor Sensor
Connector TA on PCB
(low voltage switching)
Connector TA on PCB
(low voltage switching)
Connector TA on PCB
(low voltage switching)