22
instala
r
e
installazione
Connection of flue gas discharge ducts
The appliance must be connected to a
fl
ue gas discharge
system that complies with the regulation in force and
instructions provided by the manufacturer.
When type B installation is used, the room
in which the appliance is installed must be
ventilated using a suitable air inlet which
complies with current legislation.
When installing an exhaust system, take care of the seals to
prevent any
fl
ue gas leaking into the air circuit.
R
aco
r
da
re
tu
b
ulatu
r
ă
e
v
acua
re
g
az
e
a
r
d
ere
A
paratul trebuie să
fie conectat la un sistem de evacuare a
gazelor arse ce se conformează reglementărilor în vigoare
şi instrucţiunilor furnizate de producător.
L
a
f
olos
ire
a
i
nstala
ţ
iei
d
e
t
ip
B
,
cam
er
a în
ca
re
s
e
i
nstal
e
ază a
p
a
r
atul t
re
b
u
ie
să
f
ie
v
e
nt
i
lată
f
olos
i
nd o
i
nt
r
a
re
d
e
a
er
ad
e
c
v
ată
c
e
re
s
pe
ctă l
e
g
i
sla
ţ
i
a în
v
i
g
oa
re
.
La instalarea unui sistem de evacuare ave
ţi gri
j
ă
la garnituri
,
pentru a evita pătrunderea gazelor arse în circuitul de aer.
R
aco
r
d
uri
e
l
ect
ri
ce
Pentru siguran
ţă sporită cereţi unui tehnician calificat o
verificare amănunţită a sistemului electric.
P
roducătorul nu
este responsabil pentru avariile produse de lipsa unui sis-
tem de împământare adecvat sau de defectarea sursei de
alimentare electrică.
Î
n cazul în care cablul de alimentare trebuie înlocuit, aces-
ta se va înlocui folosind piese de schimb originale.
Partea tubulaturii de evacuare ce trece prin peretele locu-
in
ţei trebuie să
fie încon
jurat
ă
d
e material izolator
(cum ar fi
p
ânză de azbest
) cu grosime de cel pu
ţin 11 mm şi lungime
de
300 mm, deoarece temperatura conductei de evacuare
poate dep
ă
şi temperatura mediului cu mai mult de
60 K.
The part of
fl
ue pipe that pass through the wall of dwelling
should be surrounded by insulated material (such as asbestos
cloth) at least 11 mm thickness and 300 mm length since
the temperature of
fl
ue pipe maybe exceed the ambient
temperature by more than 60K.
Electrical connections
For increased safety, ask a quali
fi
ed technician to perform a
thorough check of the electrical system.
The manufacturer is not responsible for any damage caused by
the lack of a suitable earthing system or by the malfunctioning
of the electricity mains supply.
In the event that the power supply cable must be changed,
replace it using original spare parts.
AV
E
RTI
S
MENT
!!
NU UMBLA
Ţ
I
LA SAU DECONECTAŢI
SENZORUL DE GAZE ARSE. ACEST
LUCRU POATE AFECTA FUNCŢIONA-
REA CORECT
Ă
A APARATULUI.
CONDIŢIILE DE TIRAJ SLAB POT DU-
CE LA REFLUXUL GAZELOR ARSE ÎN
CAMERA INSTALAŢIEI.
RISC DE INTOXICARE CU MONOXID DE
CARBON.
AV
E
RTISMENT
!!
Î
N
AINTE DE ORICE INTER
V
EN
Ţ
IE
ASUPRA
APARATULUI
,
DECONECTAŢI ÎNT
ÂI DE LA
ALIMENTAREA CU ENERGIEELECTRICĂ.
WARNING!!
NEVER TAMPER WITH OR DECOMMISSION
THE FLUE GAS SENSOR. THIS COULD
AFFECT THE PROPER OPERATION OF THE
APPLIANCE.
POOR
DRAUGHT
CONDITIONS
COULD
CAUSE EXHAUST GAS BACKFLOW INTO
THE INSTALLATION ROOM.
HAZARD
OF
CARBON
MONOXIDE
INTOXICATION.
WARNING!!
BEFORE PERFORMING ANY WORK ON THE
APPLIANCE, FIRST DISCONNECT IT FROM
THE ELECTRICAL POWER SUPPLY.