17
Removing the P.C.B.s
1. Remove the inspection cover on the reverse of the
control panel (F
IG
. 1.60);
2. Remove the screws “S1” (F
IG
. 1.65 & F
IG
. 1.66);
3. Remove the facia panel (F
IG
. 1.67);
5. Disconnect the connection cable ”T1” (F
IG
. 1.68);
6. Unplug the electrical connectors “U1” from the main
P.C.B. (Fig. 1.69);
7. Remove the main P.C.B. mounting screws “V1’ (four in
total) (F
IG
. 1.70);
8. Remove the main P.C.B. (F
IG
. 1.71);
9. Remove the display P.C.B. mounting screws “W1’ (F
IG
.
1.72);
10.Remove the display P.C.B. (F
IG
. 1.73);
11.Replace either P.C.B. in reverse order.
F
IG
. 1.67
S1
F
IG
. 1.65
F
IG
. 1.66
S1
F
IG
. 1.70
T1
F
IG
. 1.68
F
IG
. 1.69
U1
S1
S1
U1
U1
V1
V1
F
IG
. 1.71
Содержание eco Genius 24MFFI
Страница 33: ...9 FIG 1 26 FIG 1 27 Q...
Страница 42: ...18 W1 FIG 1 72 FIG 1 73 W1 W1 W1...
Страница 50: ...26 ecoGENUS 24 MFFI ecoGENUS 24 RFFI...
Страница 55: ...31...
Страница 57: ...SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Models ECOGENUS 24 RFFI SYS Edition 1 of 1 December 1999...