7. TECHNICAL INFORMATION
Certification
63AT4528
Category
II2H3B/P
Thermal Capacity min/max
kW
8/24
Usable Thermal Power min/max (30/40°C)
kW
8.8/26.1
Usable Thermal Power min/max (60/80°C)
kW
7.9/23.3
Usable Thermal Power min/max (30/50°C)
kW
-/24.5
Power for Hot Water Production min/max
kW
7.9/23.3
Efficiency at Nominal Thermal Capacity (30/50°C)
%
102.2
Efficiency at 30% of Nominal Thermal Capacity (47°C of return)
%
96.4
Efficiency at 30% of Nominal Thermal Capacity (30°C of return)
%
103.6
Gas Consumption after 10 Minutes*
m
3
0.42
Maximum Heat Loss to the Casing (
∆
T=50°C)
%
0.6
Flue Heat Loss with Burner Operating
%
2.1
Flue Heat Loss with Burner Off
%
0.2
Maximum Discharge of Fumes
Kg/h
35.1
Maximum Temperature of Discharge Fumes
°C
66.7
Temperature of Discharge Fumes when Heating 30/40°C (1 m of coax.)
°C
42.9
Minimum Room Temperature
°C
5
Heating Temperature min/max (High Temperature range)
°C
42/82
Heating Temperature min/max (Low Temperature range)
°C
30/75
Temperature of Water for Domestic Use min/max
°C
36/56
Class NOX
5
CO
2
Content
%
9.3
O
2
Content
%
4
CO Content
ppm
53.5
Inlet Pressure/Methane Gas G20 (boiler at maximum)
mbar
20
Inlet Pressure/Liquid Gas G30 - G31 (boiler at maximum)
mbar
30
Residual Discharge Head
mbar(Pa)
0.65(64)
Maximum Head Loss on Water Side (
∆
T=20°C)
mbar
200
Residual Head of System (60/80°C)
bar
0.2
Maximum Heating Pressure
bar
3
Maximum Water Content in System
l
130
Expansion Vessel Capacity
l
7
Expansion Vessel Pre-load Pressure
bar
1
Pressure of Water for Domestic Use min/max
bar
0.2/8-10
Nominal Capacity of Hot Water for Heating (residual head 0.25 bar)
l/h
820
D.H.W. Flow Rate:
∆
T=25°C
l/min
13.4
∆
T=30°C
l/min
11.1
∆
T=35°C
l/min
9.6
D.H.W. Flow Minimum Rate
l/min
2.5
Quantity of Condensed Water with a (30/40°C)
l/h
1.8
pH Condensation Value
3.5÷4
Electrical Supply
V/Hz
230/50
Power Consumption
W
130
Protection Grade of Electrical System
IP
4XD
Internal Fuse Rating
A
3.15 SLOW
Width
mm
465
Height
mm
890
Depth
mm
385
Central Heating Connections
BSP
3/4
Domestic Hot Water Connections
BSP
1/2
Gas Connection
BSP
3/4
Net Weight
Kg
45
G.C. Number
41-116-17
63AT4528
II2H3B/P
8/24
8.8/26.1
7.9/23.3
-/24.5
7.9/23.3
102.2
96.4
103.6
0.42
0.6
2.1
0.2
35.1
66.7
42.9
5
42/82
30/75
36/56
5
9.3
4
53.5
20
30
0.65(64)
200
0.2
3
130
7
1
0.2/8-10
820
---
---
---
---
1.8
3.5÷4
230/50
130
4XD
3.15 SLOW
465
890
385
3/4
1/2
3/4
44.5
41-116-03
24 MFFI
24 RFFI SYSTEM
*Calculated at 70% maximum output
23 99 84 1439 112
Manufacturer:
Merloni TermoSanitari SpA - Italy
Commercial subsidiary:
MTS (GB) LIMITED
MTS Building
Hughenden Avenue
High Wycombe
Bucks HP13 5FT
Telephone: (01494) 755600
Fax: (01494) 459775
Internet: http://www.mtsgb.ltd.uk
E-mail: [email protected]
Technical Service Hot Line: (01494) 539579
Содержание eco Genius 24MFFI
Страница 33: ...9 FIG 1 26 FIG 1 27 Q...
Страница 42: ...18 W1 FIG 1 72 FIG 1 73 W1 W1 W1...
Страница 50: ...26 ecoGENUS 24 MFFI ecoGENUS 24 RFFI...
Страница 55: ...31...
Страница 57: ...SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Models ECOGENUS 24 RFFI SYS Edition 1 of 1 December 1999...