15
Removing the D.H.W. temperature probe (N.T.C.) (MFFI
only)
1. Remove the electrical connector “K1” by pulling off
(Fig. 1.54);
2. Unscrew and remove the D.H.W. temperature probe “L1”
(F
IG
. 1.55).
K1
L1
F
IG
. 1.54
F
IG
. 1.55
M1
F
IG
. 1.56
Removing the C.H. flow temperature probe (N.T.C.)
1. Remove the electrical connector “M1” by pulling off
(Fig. 1.56);
2. Unscrew and remove the C.H.flow temperature probe
“N1” (F
IG
. 1.57).
O1
P1
F
IG
. 1.58
F
IG
. 1.59
Removing the C.H. return temperature probe (N.T.C.)
1. Remove the electrical connector “O1” by pulling off
(Fig. 1.58);
2. Unscrew and remove the C.H. return temperature probe
“P1” (F
IG
. 1.59).
N1
F
IG
. 1.57
Содержание eco Genius 24MFFI