Removing the gas valve
1. Disconnect the electrical connection “R” from the gas
valve (F
IG
. 128);
2. Release the top nut “S” (F
IG
. 1.29);
3. Remove the screws “T” from the bottom of the gas valve
pipe (F
IG
. 1.30);
4. Remove the gas valve (F
IG
. 1.31).
F
IG
. 1.29
F
IG
. 1.30
F
IG
. 1.31
T
T
Содержание eco Genius 24MFFI
Страница 33: ...9 FIG 1 26 FIG 1 27 Q...
Страница 42: ...18 W1 FIG 1 72 FIG 1 73 W1 W1 W1...
Страница 50: ...26 ecoGENUS 24 MFFI ecoGENUS 24 RFFI...
Страница 55: ...31...