36
/
SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
The parameters relating to each individual menu are listed in the
following pages.
The various parameters can be accessed and modified using the
m
eNu
/o
k
button and programming buttons
and
. (see fig.
below).
To access the Menus, open the cover and proceed as follows:
1. Press the m
eNu
/o
k
button; the first figure
0
00
will flash on the
display.
2. Press the buttons
or
to select a menu, for example:
“
2
00
3. Press the m
eNu
/o
k
button; the second figures on the display will
flash, e.g. “
2
1
0
.
Caution! The menus reserved for qualified technicians may only be
accessed after setting the access code.
4. Press the m
eNu
/o
k
button;
222
will appear on the display unit.
5. Press the buttons
or
to select code
234
6. Press the m
eNu
/o
k
button to select the sub menu; the second
figures will flash, e.g. “
2
2
0
”.
7. Press the buttons
or
to select a sub menu; for example:
“
2
3
0
8. Press the m
eNu
/o
k
button to access the sub menu parameters;
the three figures will flash, for example: “
23
0
”.
9. Press the buttons
or
to select a parameter; for example:
“
23
1
10. Press the m
eNu
/o
k
button to access the parameter; the display
will indicate the value, e.g “
70
”.
Note: The parameter value will be displayed for 20 seconds, then
will begin to flash in alternation with the parameter, e.g. “
70
>
231
.
11. Press the buttons
or
to select the new value, e.g. “
75
”.
12. Press m
eNu
/o
k
to save the change or press e
sc
to exit without
saving.
To exit, press the e
sc
button until the normal display screen is
restored.
For menus which do not require the access code, it is possible to
pass directly from the menu to the sub menu.
Accessing the settings - adjustment - problem identification
menus
The boiler can be used to manage the heating system in its entirety.
Navigation within the menus enables the boiler connected
peripheral units to be customised, optimising operation for
maximum comfort and maximum saving. It also provides important
information relating to the efficient operation of the boiler.
The following menus are available:
2 Boiler Parameter
2 1 Service code (234)
2 2 General setting
2 3 C.H. Parameters - Part 1
2 4 C.H. Parameters - Part 1
2 5 Do not use
2 9 Menu 2 Reset to factory setting
3 Solar & Storage
3 0 General setting
3 1 Service code (234)
3 2 Special setting
4 Zone 1 Parameters
4 0 Set-point Zone1
4 1 Service code (234)
4 2 Zone 1 Setting
4 3 Diagnostics
4 4 Zone device mangement
5 Zone 2 Parameters
5 0 Set-point Zone2
5 1 Service code (234)
5 2 Zone 2 Setting
5 3 Diagnostics
5 4 Zone device mangement
5 5 Multizone
7 Test & Utilities
8 Service Parameter
8 1 Service code (234)
8 2 Boiler
8 3 Boiler Temperature
8 4 Don’t use
8 5 Service
8 6 Statistics
8 7 E@sy - NOT ACTIVE
8 8 Error History
p
rogrammiNg
buttons
Menu/Ok button
Содержание CLAS HE R
Страница 26: ...26 INSTALLATION S Plan system utilizing integral 2 channel programmer and Ariston unvented hot water cylinder ...
Страница 27: ... 27 INSTALLATION Y Plan system utilizing external 2 channel programmer ...
Страница 28: ...28 INSTALLATION Y Plan system utilizing integral 2 channel programmer ...
Страница 61: ......
Страница 62: ......
Страница 63: ......