22
/
INSTALLATION
Table of flue gas exhaust duct lengths
S1 = Air intake S2 = Flue gas exhaust
S1 = S2 - Air intake and flue gas exhaust equal lengths
S1 + S2 - Air intake and flue gas exhaust unequal lengths
FLUE TYPE
Maximum Extension
Exhaust-air (m)
Diameter
of pipe
(mm)
CLAS HE R
24 EU
C
oaxial S
yst
em
C13
C33
C43
12
ø 60/100
C13
C33
C43
36
ø 80/125
Twin-pipe S
yst
em
S1 = S2
ø 80/80
C13
36
C33
60
C43
C53
S1 + S2
84
ø 80/80
TYPE C13
TYPE C33
TYPE C53
TYPE C33
TYPE C33