MAINTENANCE GUIDE
5 ANNUAL MAINTENANCE
Ignition & detection electroded
Maintenance Interval : Annually
How : Visual inspection / Clean as necessary / Distance from the burner /
Ionisation current more than 1 µA
Burner
Maintenance Interval : Annually
How : Visual inspection / Clean as necessary
Fan
Maintenance Interval : Annually
How : Visual inspection / Clean as necessary
Primary heat exchanger
Maintenance Interval : Annually
How : Visual inspection / Clean as necessary
Condensate trap
Maintenance Interval : Annually
or after cleaning primary heat exchanger
How : Visual inspection / Clean as necessary /
Add water before replacing