18
/
INSTALLATION
Fitting the 5” Flue
(Ø 80 / 125 Horizontal/vertical)
Once the boiler has been positioned on the wall, it is necessary to
insert the Ø80/125 adaptor (Fig. 5) for both horizontal and vertical
flue runs into the boiler flue socket (not supplied with flue kit - Part
No 3318095).
Push the adaptor onto the boilers flue connection, grease the seals
then add extensions or elbows as required, secure the adaptor,
using the clamp and screws provided.
To fit extensions or elbows it is first necessary to ensure that the lip
seal is fitted correctly into the inner flue, once verified, it is simply
necessary to push them together, no clamps are necessary to secure
the flue components.
Before proceeding to fit the flue, ensure that the maximum flue
length has not been exceeded (See the tables) and that all elbows
and bends have been taken into consideration, for each additional
90° elbow 1 metre must be subtracted from the total flue length,
and for each 45° 0.5 metres must be subtracted from the total flue
length (the height of the vertical adaptor and a 45° bend can be
seen in Fig.6 and a 90° bend in Fig. 7).
Note: DO NOT cut the vertical flue kit.
180 mm
Total length
of Vertical Kit
1240 mm
5" Adaptor
Part no: 3318095
* This length will vary
according to the type
of flashing installed
Useable length
of Vertical flue
575 mm*
Fig. 5
Clamp
Seal
Screws
Fig. 4
Fig. 6
Fig. 7
Содержание CLAS HE R
Страница 26: ...26 INSTALLATION S Plan system utilizing integral 2 channel programmer and Ariston unvented hot water cylinder ...
Страница 27: ... 27 INSTALLATION Y Plan system utilizing external 2 channel programmer ...
Страница 28: ...28 INSTALLATION Y Plan system utilizing integral 2 channel programmer ...
Страница 61: ......
Страница 62: ......
Страница 63: ......