37
SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
menu
sub
-menu
Par
amet
er
Description
value
default setting
2 BOILER PARAMETER SETTING
2
1 Entering access code
222 press the programming "+" button to
select 234 and press the m
eNu
button
2
2 BOILER GENERAL SETTING
2
2
0 Slow ignition
0 to 99
60
RESERVED FOR SAT
2
2
1 Minimum ambient temperature for antifreeze
activation
from 2 to 10 °C
5
Activated
only
with the modulating
peripheral device (optional)
2
2
2 NOT PRESENT
2
2
3 Underfloor thermostat or zone 2 ambient thermostat
selection
0 = Underfloor safety thermostat
1 = Zone 2 ambient thermostat
1
Do not modify
2
2
4
NOT PRESENT
2
2
5 NOT PRESENT
2
2
6 NOT PRESENT
2
2
7 NOT PRESENT
2
2
8 Boiler Version
Do not modify
0 to 5
0
RESERVED FOR TECHNICAL
ASSISTANCE Only if the PCB is
changed
2
3 BOILER PARAMETER - PART 1
2
3
0 NOT PRESENT
2
3
1 Maximum heating power setting
0 to 99
see the "gas setting" table, in
commissioning
2
3
2 Domestic hot water maximum RPM percentage
CANNOT BE MODIFIED
0 to 99
RESERVED FOR TECHNICAL
ASSISTANCE Only if the gas or PCB is
changed
see "gas setting" table in
commissioning
2
3
3 Minimum RPM percentage
CANNOT BE MODIFIED
0 to 99
2
3
4 Heating maximum RPM percentage
CANNOT BE MODIFIED
0 to 99
2
3
5 Selection of ignition delay type when heating
0 = Manual
1 = Automatic
1
see section on "gas setting" in
commissioning
2
3
6 Ignition delay when heating timer setting
from 0 to 7 minutes
3
2
3
7 Post-circulation when heating
from 0 to 15 minutes or OC (AC)
3
2
3
8 NOT PRESENT
2
3
9 NOT PRESENT
2
4 BOILER PARAMETER - PART 2
2
4
0
NOT PRESENT
2
4
1
NOT PRESENT
2
4
2
NOT PRESENT
2
4
3 Post-ventilation after heating request
0 = OFF
1 = ON
0
2
4
4 Time delay after heating temperature increase
from 0 to 60 minutes
16
activated only with thermostat On/
Off and heating control activated
(parameter 421 or 521 = 01
This parameter allows the time delay to be set before automatic increase of the flow temperature calculated in increments of 4°C (max 12°C). If this
parameter retains the value 00, this function is not active.
2
4
5 NOT PRESENT
2
4
6 NOT PRESENT
2
4
7 Device indicator for heating circuit pressure
0 =
temperature sensor only
1 = pressure switch at minimum
2 = pressure sensor
0
RESERVED FOR TECHNICAL
ASSISTANCE Only if the PCB is
changed
2
4
8 NOT PRESENT
2
5 DOMESTIC HOT WATER PARAMETER
2
5
0 NOT PRESENT
2
5
1 NOT PRESENT
2
5
2 NOT PRESENT
Содержание CLAS HE R
Страница 26: ...26 INSTALLATION S Plan system utilizing integral 2 channel programmer and Ariston unvented hot water cylinder ...
Страница 27: ... 27 INSTALLATION Y Plan system utilizing external 2 channel programmer ...
Страница 28: ...28 INSTALLATION Y Plan system utilizing integral 2 channel programmer ...
Страница 61: ......
Страница 62: ......
Страница 63: ......