Fabric and Fan-only Module Description
5. Return the lock-levers to the closed position, securing the module to the chassis (
B.2
Handling Fan-only Modules
DCS-7304 Fabric and Fan-only Module (left)
depicts a DCS-7304 chassis with installed fabric modules
(slots 1 and 2) and fan-only modules (slots 3 and 4). Lock-levers are shown in the open (slot 3) and
closed (slot 4) position
DCS-7304 Fan-only Module (right)
displays the position of the lock lever
release screw (below the extended handles).
The fan direction indicator is located below the top handle. Refer to
configuration requirements.
The following configuration is mandatory when fan-only modules are installed:
•
Slots 1 and 2 contain fabric modules
•
Slots 3 and 4 contain fan-only modules
Figure 35: DCS-7304 Fabric and Fan-only Module (left); DCS-7304 Fan-only Module (right)
1
Lock lever release
screw
3
Lock lever release
screw
2
Fan airflow direction
(color indicates airflow
direction)
B.2.1
Removing Fan-only Modules
This procedure describes the proper method for removing fan-only modules from the switch:
1. Release the lock-levers from the module frame by rotating each handle’s release screw counter-
DCS-7304 Fan-only Module (right)
).
2. Extend the lock-levers towards the top and bottom of the chassis (
).
3. Use the lock-levers to pull the module three to four inches from the installed position.
4. Return the lock-levers to the closed position.
5. Grasp the module frame and pull the module until it is completely outside of the chassis.
45
Содержание 7300 Series
Страница 2: ......
Страница 16: ...12 ...
Страница 26: ...22 ...
Страница 34: ...30 ...
Страница 54: ...50 ...
Страница 58: ...54 ...
Страница 60: ...DCS 7308 and DCS 7328 Rear Panel 1 ESD grounding port 2 Fabric modules 3 Fan modules 56 ...
Страница 61: ...Rear Panels DCS 7316 Rear Panel 1 ESD grounding port 2 Fabric modules 3 Fan modules 4 Power Supply Modules 57 ...
Страница 62: ...58 ...
Страница 66: ...62 ...