1. Install the mounting ear on the front post by inserting the front rack plugs (if present) and guide pins
in the racks specified for the switch model that is being installed (
Figure 13: Attaching the Right
).
Figure 13: Attaching the Right Mounting Ear
1
Front right rack post
If rack plugs are not present, align the threaded holes and attach the mounting ears with screws.
2. If applicable, close the front locking mechanism latch (
).
3.2.3.3
Inserting the Switch into the Rack
1. Rotate the stabilizer bar from the left shelf toward the right shelf such that the nob at the end of the
stabilizer bar inserts into the notch at the rear of the ledge of the right shelf.
Figure 14: Both Switch Shelves Installed
20