67
restart a halted scanner port, the initialization function,
InitScanner1, must be called. It is recommended that the scanner
port should be stopped if the barcode decoding is not required for a
long period of time.
Returns
:
none
InitScanner1
Purpose
:
Initialize respective scanner port.
Syntax
:
void InitScanner1(void);
Example call
:
InitScanner1( );
Includes
:
InitScanner1( );
while(1){if(Decode( )) break;}
Use InitScanner1 function to initialize scanner port. The scanner
port won't work unless it is initialized.
Byte Bit
Description
7
1 : Enable Code 39
0 : Disable Code 39
6 Reserved
5 Reserved
4 Reserved
3
1 : Enable Interleave 25
0 : Disable Interleave 25
2 Reserved
1
1 : Enable Codabar
0 : Disable Codabar
0
0
1 : Enable Code 93
0 : Disable Code 93
7
1 : Enable Code 128
0 : Disable Code 128
6
1 : Enable UPCE no Addon
0 : Disable UPCE no Addon
5
1 : Enable UPCE Addon 2
0 : Disable UPCE Addon 2
4
1 : Enable UPCE Addon 5
0 : Disable UPCE Addon 5
Description
:
1
3
1 : Enable EAN 8 no Addon
0 : Disable EAN 8 no Addon
Содержание PT-10