![Arctic Cat ZR 120 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/arctic-cat/zr-120/zr-120_service-manual_2965380036.webp)
35
1. Open the hood; then disconnect the handlebar
warmer two-wire connector.
2. Connect one ohmmeter lead to the green/white lead;
then connect the other ohmmeter lead to the yellow
lead.
YM-143A
3. The meter must read 14.4 ± 10% ohms.
4. Replace any element measuring less than or more
than the specified amount.
5. Repeat test for the other element; then connect the
leads. Close and latch the hood.
Testing Handlebar Warmer
Switch
1. Open the hood; then disconnect the main harness
wires from the switch.
2. With the handwarmer toggle in the OFF position,
connect one ohmmeter lead to pin and the other ohm-
meter lead to pin. The meter must read 1 ohm or less
resistance.
YM-145
3. With the handwarmer toggle in the ON position, con-
nect one ohmmeter lead to pin and the other ohmme-
ter lead to pin. The meter must read 1 ohm or less
resistance.
4. Connect the green/white wire to the bottom terminal
and the brown wire to the top terminal on the switch.
YM-144