5. Use the up or down arrows to correct the
water temperature as required.
6. After 5 seconds the correction is memorised
and the display stops flashing. The unit will
now operate as normal.
Proper disposal (electrical waste)
The labeling on the product and on the
accompanying literature declares that it must
not be disposed of, at the end of its service life,
with the ordinary household rubbish.
Please dispose of this equipment separately
from other waste, to protect the environment
and public health from damage by unregulated
waste disposal. Recycle the equipment and
support the sustained recycling of material
resources.
Users should contact their retailer or the
responsible civic authorities for advice on how
to recycle the equipment in an environmentally
friendly way.
Common Problems and Solutions
The display does not
light up
No electrical supply
Blocked air filter
Ambient temperature
too high
Obstructed ventilation
Water is not circulating
properly
Clean the air filter as explained in ‘Regular Maintenance’
Re-establish optimum ambient temperature conditions (the maximum
ambient temperature for the chiller is 35°C)
Check that the ventilation panels in your cabinet have not become
clogged or obstructed
Check the hoses for obstructions and kinks
Check that the pump is operating correctly
If one (or both) fans is not operating contact your Arcadia retailer
Hoses have insufficient
insulation
Damaged Fan
If hoses are particularly long they should be insulated and
reduced in length as much as possible
Water temperature display
needs re-calibration
Recalibrate the display (see below)
Check that the electrical supply to the unit is connected at the wall and
at the chiller, that the switch at the electrical outlet (if applicable) is on
and that the power switch at the chiller is in the I (on) position
Check the fuse in the chiller plug and the circuit breaker or fuse at
your electrical distribution box
Problem
Cause
Solution
The chiller does not bring
down the temperature of
the aquarium sufficiently
Clean the air filter following the instruction “Operation of cleaning”
Dirty air filter
Ambient temperature
too high
Clear the obstruction to the panel and if necessary relocate the chiller
Obstructed ventilation panel
Contact a retailer
Contact a retailer
Broken ventilation system
Damage of the water’s
temperature probe
On the display appears
the message “AL”
On the display appears
the message “E1”
Contact a retailer
Damage of the
overheating probe
On the display appears
the message “E2”
The temperature
displayed is not the
temperature of the water
in the aquarium
Having checked the above you have been unable to resolve the problem, please contact your Arcadia retailer.
Re-establish the optimal ambient conditions.
(The maximum ambient temperature allowed is 35°C)
UK
5
Installation and Maintenance Instructions