16 Technical Data
ARCA Regler GmbH
44 / 46
Series 824
09.2018 / 1.0
16.4
Electrical data for options – potentiometer and position
feedback
Potentiometer
824.P/Exxx-xx2
Resistance
200, 500 or 1000 Ohm
4)
Characteristic deviation
< 2 %
5)
Internal capacitance Ci
3.5 pF
Internal inductance Li
10 mH
Electrical connection
[11.3.1]
Feedback potentiometer
Position transducer 3L
824.P/Exxx-xx3
3-wire circuit
RWG, type 4522
Operating voltage
15 to 24 V DC
Output
4(0) - 20 mA, short-circuit proof
Current limitation
at approx. 28 mA
Load Ri
0 - 400 Ohm
Characteristic deviation
< 2 %
5)
Electrical connection
[11.3.2]
Position transducer 3-wire
Position transducer 2L
824.P/Exxx-xx4
2-wire circuit
RWG, type TMT 136R
Supply voltage
DC 8.5 ... 36 V
Output
4 - 20 mA, short-circuit proof
Current limitation
at approx. 36 mA
Load Ri
1300 Ohm at 36 V DC
Characteristic deviation
< 2 %
5)
Electrical connection
[11.3.3]
Position transducer 2-wire
1) Permissible ambient temperature for other circuits on enquiry.
2) Special version down to -40 °C (pressure dew point < -50 °C).
3) Special version NPT ¼".
4) Zero point and range setting must be done on the receiving device.
5) A deviation of up to 5% is possible, depending on the method of mounting the positioner or the stroke range.
Содержание 824 series
Страница 1: ...Operating manual Electro pneumatic positioners Series 824 09 2018 1 0...
Страница 2: ...Original instructions ARCA Regler GmbH All rights reserved Cover picture background Freepik com...
Страница 14: ...6 Exploded view ARCA Regler GmbH 14 46 Series 824 09 2018 1 0 6 Exploded view Illustration 2 Detail drawing...
Страница 23: ...ARCA Regler GmbH 9 Installation Series 824 23 46 09 2018 1 0 Illustration 6 Pivot lever...
Страница 26: ...9 Installation ARCA Regler GmbH 26 46 Series 824 09 2018 1 0 Illustration 9 Adapter plate pivot lever...
Страница 46: ...www arca valve com...