ARCA Regler GmbH
16 Technical Data
Series 824
43 / 46
09.2018 / 1.0
Air consumption
< 0.6 m3/h in the normal state, type 824.P < 0.5 m3/h in the
normal state in stationary operation
Flow rate
6 m3/h in the normal state at 1.4 barg
Electrical / pneumatic data for the base device
pneumatic
not explosion proof
Electrical
connection
[11.1]
I/P transducer
Input signal
0.2 to 1 bar
0/4 to 20 mA
Split ranges
0.2 to 0.6 to 1 bar
0/4 to 10 / 12 to 20 mA
Load
resistor
170 Ώ
Required
load voltage
3.4 V
16.3
Electrical data for options – inductive limit value transmitter
Limit value transmitter N
824.P/Exxx-x1x
Normal version
2-wire technology in accordance with DIN 19234 (NAMUR),
for downstream switching amplifiers
2 slot-type initiators
Type SJ 3.5 N
Function
NC, normally closed
Switching difference
< 1 %
Control circuit
see downstream switching amplifier
EMC according to
EN 60947-5-2 and DIN 19234
Electrical connection
[11.2.1]
Normal version (2-wire, N)
Limit value transmitter SN 824.P/Exxx-x2x
Safe design
2-wire technology according to DIN 19234 (NAMUR) for customer
provided
switching amplifier in safe design
2 slot-type initiators
Type SJ 3.5 SN
Function
NC, normally closed
Switching difference
< 1 %
Control circuit
see downstream switching amplifier
EMC according to
EN 60947-5-2 and DIN 19234
Electrical connection
[11.2.2]
Safe design (2-wire, SN)
Limit value transmitter E2
824.P/Exxx-x3x
Direct-switching
3-wire technology with integrated switching amplifier
for direct switching
2 slot-type initiators
Type SB 3.5 E2
Function
NO, normally open
Switching difference
< 1 %
Operating voltage
10 to 30 V DC
perm. load current
100 mA
Electrical connection
[11.2.3]
Direct switching version (3-wire, E2)
Содержание 824 series
Страница 1: ...Operating manual Electro pneumatic positioners Series 824 09 2018 1 0...
Страница 2: ...Original instructions ARCA Regler GmbH All rights reserved Cover picture background Freepik com...
Страница 14: ...6 Exploded view ARCA Regler GmbH 14 46 Series 824 09 2018 1 0 6 Exploded view Illustration 2 Detail drawing...
Страница 23: ...ARCA Regler GmbH 9 Installation Series 824 23 46 09 2018 1 0 Illustration 6 Pivot lever...
Страница 26: ...9 Installation ARCA Regler GmbH 26 46 Series 824 09 2018 1 0 Illustration 9 Adapter plate pivot lever...
Страница 46: ...www arca valve com...