Flex EPV Instruction Manual (CE)
April 2020 v1.0
Page 48 of 71
A V
4.2.6.17 PB3 & PB4 Analog Output Programming (PB3&4 ANALOG)
This function requires transmitter pushbuttons (in pairs) configured to proportional
stepless pushbuttons and their designated receiver outputs equipped with the analog
module.
1) Press the ENTER button to enter analog output type setting (cursor shown next
to VOLTAGE, CURRENT or OFF).
2) Press the UP/DOWN buttons and then the ENTER button to scroll and select between
Voltage Outputs, Current Outputs or Off (analog outputs disabled).
Voltage Outputs:
3) Press the UP/DOWN buttons and then the ENTER button to scroll and select
between Minimum, Neutral and Maximum voltage outputs (cursor shown under the
first digit to the far left). Press the UP/DOWN buttons to scroll and select voltage
value, and then the ENTER button to go to the next digit to the right. Press the
ENTER button repeatedly to cycle through the 3-digit voltage value. Press the
UP/DOWN buttons to change value.
4) Press the BACK button to return to step #3 above. Press it again to go back to
step #1. Press it again to go back to PB3 & PB4 Analog Output Programming
(cursor shown next to PB3&PB4 ANALOG).
5) Press the UP/DOWN buttons to scroll through other system settings.
* Make sure the selector switch on analog module is set to “V” position
for voltage outputs.
Current Outputs:
6) Press the UP/DOWN buttons and then the ENTER button to scroll and select
between Minimum, Neutral and Maximum current outputs (cursor shown next to the
2-digit current value). Press the UP/DOWN buttons to scroll and select current
output value.
7) Press the BACK button to return to step #6 above. Press it again to go back to step
#1. Press it again to go back to PB3 & PB4 Analog Output Programming (cursor
shown next to PB3&PB4 ANALOG).
8) Press the UP/DOWN buttons to scroll through other system settings.
* Make sure the selector switch on analog module is set to “A” position
for current (amperage) outputs.
>PB3&4 ANALOG
VOLTAGE
MAX 10.0V
NEU 00.0V
MIN 10.0V
UP DOWN ENTER BACK
>PB3&4 ANALOG
CURRENT
MAX 20mA
NEU 00mA
MIN 20mA
UP DOWN ENTER BACK
>PB3&4 ANALOG
OFF
UP DOWN ENTER BACK