Flex EPV Instruction Manual (CE)
April 2020 v1.0
Page 40 of 71
>TYPE:
000
UP DOWN ENTER BACK
>S/N:
0000001
UP DOWN ENTER BACK
4.2.6.1 System Serial Number (S/N)
For safety measure, system serial number can only be changed via the IR
programmer unit. Please contact ARC representative for more details. Press the
UP/DOWN buttons to scroll through other system settings
4.2.6.2 System Type Programming (TYPE)
System type number is associated with functions such as the dual-crane tandem
operation, multiple-receiver operation, and random-access operation. Please contact
ARC representative for more details.
1) Press the ENTER button to enter system type setting (cursor shown next to the
3-digit type value).
2) Press the UP/DOWN buttons to scroll and select type value as a whole (000~512).
3) Or press the ENTER button again to change the 3-digit type value individually
(cursor shown under the first digit to the far left). Press the UP/DOWN buttons to
scroll and select, and then the ENTER button to go to the next digit to the right.
Press the ENTER button repeatedly to cycle through the 3-digit type value. Press
the UP/DOWN buttons to change value.
4) Press the BACK button to return to step #1 above. Press it again to go back to
System TYPE Programming (cursor shown next to TYPE).
5) Press the UP/DOWN buttons to scroll through other system settings.
4.2.6.3 System Frequency Programming (FREQ)
For safety measure, system frequency range can only be changed via the IR
programmer unit. Please contact ARC representative for more details. Press the UP/
DOWN buttons to scroll through other system settings
>FREQ:
433.050
UP DOWN ENTER BACK
Содержание FLEX EPV
Страница 1: ...FLEXEPV Instruction Manual ...