4.2.6.9 Brake Function Programming (BRAKE)
Please refe to section 4.2.5 for various types of brake functions available.
For 2-
step/speed pushbuttons only.
1) Press the ENTER button to enter brake function type setting (cursor shown
next to DG1 or other setting previously programmed).
2) Press the UP/DOWN buttons to scroll and select.
3) Press the BACK button to go back to Brake Function Programming (cursor
shown next to BRAKE).
4) Press the UP/DOWN buttons to scroll through other system settings.
4.2.6.10 PB1 & PB2 Relay Output Programming (PB1&2 RELAY)
Please refe to section 4.2.2 for various types of relay actions available. This function
requires transmitter pushbuttons (in pairs) configured to 1, 2 or 3-step pushbuttons
and their designated receiver outputs equipped with the 2-step or 3-step relay
modules.
1) Press the ENTER button to enter relay output type setting (cursor shown next to
the 8-digit relay output type value).
2) Press the UP/DOWN buttons to scroll and select relay output type as a whole.
3) Or press the ENTER button again to change the 8-digit relay output type
individually (cursor shown under the first digit to the far left). Press the UP/DOWN
buttons to scroll and select between 0 and 1, and then the ENTER button to go to
the next digit to the right. Press the ENTER button repeatedly to cycle through the
8-digit relay output type. Press the UP/DOWN buttons to change value.
4) Press the BACK button to return to step #1 above. Press it again to go back to
PB1 & PB2 Relay Output Programming (cursor shown next to PB1&PB2 RELAY).
5) Press the UP/DOWN buttons to scroll through other system settings.
>BRAKE
DG1
UP DOWN ENTER BACK
>PB1&2 RELAY
00000000
UP DOWN ENTER BACK
Содержание FLEX EPV