Flex EPV Instruction Manual (CE)
April 2020 v1.0
Page 37 of 71
4.2.3 Jumper Functions
Refer to section 4.2.6.22 jumper function programming.
Jumper Settings
Function
JP3
(Open)
Standard A/B selector sequence
- Output
relay A activated at A position, output relay B activated at B position,
both relays activated at A+B position.
JP3
(Short)
Reversed logic A/B selector sequence
- Output
relay B activated at A position, output relay A activated at B position,
both relays deactivated at A+B position.
JP6
(Short)
System firmware version
JP7
(Short)
For system testing only (receiver MAIN relays disabled)
JP8
(Open)
Receiver-to-transmitter remote pairing
(pressing the Pairing button required)
JP8
(Short)
Receiver-to-transmitter remote pairing
(pressing the Pairing button not required)