INSTALLATION OF ULTRASOUND SENSORS
It is the installer responsibility to check that all indications described are complied with.
Precautions to follow for a long-lasting installation:
• Fix the sensor to a strong structure.
• Protect sensor body and connector with a guard.
• Keep sensor sensitive surface clean.
• Clean only with a soft wet cloth.
• Do not use aggressive detergents or products.
• Do not clean equipment with direct water jets.
Fig. 3
Yellow LED
Yellow LED
Green LED
Green
LED
CONNECTOR
Not connected
+ 12 V
GND
PIN
M12x1, 5-pin
Not connected
Analogue output
POSITION
COLOR
CONNECTION
1
Brown
+ 12 V
2
--
Not connected
3
Blue
GND
4
Black
Analogue output
5
--
Not connected
Fig. 4
Driving direction
(FORWARD)
INSTALLATION ORIENTATION
Connector
Sensitive flat
surface
Fixing holes
For a correct operation, respect the installation direction (
Fig. 4
).
INSTALLATION
WARNING: CONNECTOR PINOUT IS PROVIDED ONLY TO MAKE ANY SYSTEM
DIAGNOSIS EASIER FOR TECHNICIANS / INSTALLERS.
THE ULTRASONIC SENSORS MUST NOT BE MODIFIED AND/OR
REPLACED WITH DIFFERENT TYPES OF SENSORS SINCE THEY COULD
CAUSE FIRES OR DAMAGE THE BOOM.