Menu > Settings > BLC > Sensor settings
SYSTEM WITH 2 SENSORS
Fig. 18
Fig. 19
Number of sensors
:
2
(
US1
+
US2
).
Number of ultrasonic sensors used by the BLC control.
EXTERNAL SENSORS
Fig. 20
External sensor posit. x1
: indicates the distance between center
C
(point
zero) and
US1
sensor.
The value must be negative
(
Fig. 21
).
External sensor posit. y1
: indicates the
LV
distance between the sensitive
surface of sensor
US1
and the outlet of the nozzles (
Fig. 22
).
The sensitive surface must be positioned ALWAYS HIGHER than the outlet
(
LV
> 0 mm).
External sensor posit. x2
: indicates the distance between center
C
(point
zero) and
US2
sensor.
The value must be positive
(
Fig. 21
).
External sensor posit. y2
: indicates the
LV
distance between the sensitive
surface of sensor
US2
and the outlet of the nozzles (
Fig. 22
).
The sensitive surface must be positioned ALWAYS HIGHER than the outlet
(
LV
> 0 mm).
Fig. 21
SENSITIVE SURFACE
OF THE SENSOR
OUTLET
OF THE NOZZLES
Fig. 22
SETTINGS