9.18
Type of control (Menu 70.0)
The system can be equipped with: fl ow meter, pressure transducer or both.
This parameter tells the computer which device to use for calculating the fl ow rate and controlling
delivery.
If both the fl ow meter and the pressure transducer are installed, we recommend
setting the fl ow meter as control reference device: the nozzles are subject to wear
which may compromise the reliability of control via the transducer.
• Flow meter control: corresponds to programming option "
"
• Transducer control: corresponds to programming option "
"
• Access programming as described in
par. 9.9 - Access to advanced program-
ming
1) Press in sequence to scroll through the
parameters in the Advanced Menu, and
select Menu 70.0
2) Press in sequence to set the type of
control
During data modification:
A) Press to confirm the new value
B) Press to exit without modifying the
value