35
English
9.17 Pressure
transducer
The pressure transducer reads the operating pressure during treatment, and also enables the
computer to calculate the fl ow and delivery rates if a fl ow meter is not installed.
This parameter indicates that the transducer is installed on the system:
• No transducer: corresponds to programming option "
"
• Transducer present: corresponds to programming option "
"
TRANSDUCER SETTINGS
MENU 65.0
• Access programming as described in par.
9.9 - Access to advanced programming
1) Press in sequence to scroll through the
parameters in the Advanced Menu, and
select Menu 65.0
2) Press in sequence to indicate that the
transducer is present
During data modification:
A) Press to confirm the new value
B) Press to exit without modifying the value
9.17.1 Manual pressure value setting
This value indicates the pressure value corresponding to the sensor’s full-scale reading.
Enter the pressure value corresponding to the sensor’s full-scale reading.
• code. 466120.200
= enter 50.0 bar / 725 psi
• code. 466120.500
= enter 100.0 bar / 1450 psi
MANUAL PROGRAMMING
MENU 65.0
• Enter Menu 60.0 and set transducer pre-
sent by choosing option "
" during the
described transducer setting procedure
1) Press to set the transducer full-scale
value
During data modification:
A) Press to modify the value of the number
being set
B) Press to select the next number (the
selected number will flash on the display)
C) Press to confirm the new value
D) Press to exit without modifying the value