IMPLEMENT SETTINGS
Quits without confirming the
changes
Saves the changes
Cancel
Exits
Confirm
Goes back to previous menu,
or scrolls the pages of a menu
(previous page)
Scrolls the pages of a menu
(next page)
Goes back to main screen
Saves the changes to current
page
4
5
6
2
1
Fig. 68
AUXILIARY INPUTS
1
2
1
2
3A
3B
1
Select the type of auxiliary input:
Direct / Sequential / Joystick
2
Select the number of hydraulic controls of the Auxiliary Input connected to the VT:
0 / 7 / 9
.
If the system does NOT have IBX100 Hydraulic, select zero in the HYD entry.
3A
Available ONLY if
Sequential
is selected in the previous item.
If the sequential panel has the control of the central section (total number of sequential
switches 2 + 1 direct) choose
Yes
.
If it does not have it (total number of sequential switches 2) choose
No
.
3B
Available ONLY if the
Direct
option is selected in the previous item.
Indicate the number of section switches. Available options:
4 / 5 / 6 / 7
.
4
Enable / Disable
automatic function assignment for the connected Auxiliary Input.
5
Enable/ Disable
the auxiliary input selected in point
1
.
6
Enable / Disable
the displayed controls, linked to the selected Auxiliary Input type.
9
10
11
12
13
14
Fig. 69
TASK CONTROLLER
The VT can make some functions through the TC, ONLY IF THEY ARE enabled in this screen:
9
Enable / disable
the job total counter control.
10
Enable / disable
the automatic section control.
11
Enable / disable
the use of prescription maps for treatments with variable application.
TIMING
The correct management of valve timing, set on implement OP (IBX100), may vary based on the
connected VT.
12
Indicate the time between the moment when the command is sent to the valves and the actual
moment in which product output starts.
13
Indicate the time between the moment when the command is sent to the valves and the actual
moment in which product output stops.
14
Adjustment parameter for variable applications (with the use of prescription maps): this datum is
used to indicate the advance time of application rate adjustment when the machine approaches the
area changeover of the prescription map.
11.12
Home > data and settings > implement settings > Rate controller
Allows configuring the activation of the alarms relating to application rate display and regulation:
1 / 2
Rate regulation cutoff
:
-
Regulation cutoff
: Indicate the percentage of tolerance relative to the application rate target beyond which the control valve no longer regulates
because it considers it to have been reached.
Rate display cutoff
:
-
Display cutoff
: Indicate the rate display tolerance percentage beyond which the alarm is triggered and the system displays the actual rate value.
Within the set percentage, the system continues displaying the preset rate even if different from the actual one.
2 / 2
Regulation settings
:
-
Valve
: displays the type of selected control valve.
-
Aggressiveness
: Checks the power applied by the selected valve to regulate the system flow.
It reduces aggressiveness. /
It increases aggressiveness.
The ideal calibration is achieved when the application rate remains constant even with minor variations in driving speed.