79
End oF PAR. 13.2 - FUncTIonS LIST - PAGE 2
13.2.6
F7
GPS
Press
F7
to display the data transmitted by the GPS receiver (Fig. 271).
Fig. 270
Fig. 271
13.2.7
F8
Pressure
Activate the "zero" setup procedure of pressure sensor.
Fig. 272
Fig. 273
In case a pressure value is display
despite the absence of pressure inside the circuit
, it is necessary to perform zero setup of the sensor:
1
Press
F8
to display the
Pressure sensor zero calibration
screen (Fig. 273).
2
Press
OK
to reset the pressure sensor residual signal.
Bravo 400 automatically quits the procedure and displays the job screen with the pressure value of
0.0 bar
.
Value out of range!
.
This alarm appears when abnormal pressure values have been detected: check sensor for correct operation.
if problem persists, check for residual pressure in the system.
WORK FUNCTIONS - PAGE 2