28
ADVANCED PROGRAMMING - MACHINE SETTINGS
10.5 - Pressure sensor
Fig. 61
In this menu it is possible to set the data of the pressure sensor installed on the system.
The following table shows the values automatically set by selecting the sensor code (anyway, they can be modified).
aRag pReSSuRe SenSoR
TYPE
Max pressure (bar)
ARAG 466113.200
20.0
ARAG 466113.500
50.0
Other
20.0
The pressure sensor has a different use according to the situations.
• Flowmeter enabled:
displays the job pressure when the machine operates within the flowmeter limits.
When the flowmeter operates outside the limits the measured pressure is used to calculate the spray rate.
• Flowmeter disabled:
the pressure sensor is always used to calculate the spray rate.
10.5.1 - Pressure sensor
Fig. 62
Indicate the type of pressure sensor installed.
When the option
Disabled
is activated, the item
Maximum pressure
is no longer displayed (Fig. 61).
10.5.2 Maximum pressure
Fig. 63
Indicate the full scale relevant to the pressure sensor installed on the system.
Par.
9.4
Exit
function or
datum
change
Increase /
decrease
data
Scrolling
menu
pages
Shift
the
cursor
Confirm
access or
datum
change
Reset /
disable
data
Scrolling
menu
items