30
10.7 - Filling flowmeter
Fig. 67
In this menu it is possible to set the data of the filling flowmeter installed on the system.
The following table shows the values automatically set by selecting the flowmeter code (they can be also modified).
oRion floWmeteRS
Wolf floWmeteRS
TYPE
Constant
(pls/l)
Min. rate
(l/min)
Max. rate
(l/min)
TYPE
Constant
(pls/l)
Rate
min. (l/min)
Rate
max. (l/min)
462xxA4xxxx
300
10.0
200.0
462x4xxx
250
10.0
200.0
4622xA5xxxx
150
20.0
400.0
462x5xxx
132
20.0
400.0
4622XA6XXXX
100
30.0
600.0
462x7xxx
60
40.0
800.0
Other
625
10.0
200.0
10.7.1 Type
Fig. 68
Indicate the type of flowmeter installed.
When the option
Disabled
is active, the items
Minimum flowrate
,
Maximum flowrate
(Fig. 67)
and
Constant
are no longer displayed.
10.7.2 Constant
Fig. 69
Indicate the constant relevant to the filling flowmeter installed on the system.
ADVANCED PROGRAMMING - MACHINE SETTINGS
Par.
9.4
Exit
function or
datum
change
Increase /
decrease
data
Scrolling
menu
pages
Shift
the
cursor
Confirm
access or
datum
change
Reset /
disable
data
Scrolling
menu
items