Wet Stove Installation Guide
5.7
Sealing the back and base of inset stoves to a fire
surround
In order for the stove to operate correctly and at maximum efficiency
it is necessary to achieve a good seal between the back face of the stove
convector section, the stove back base sections and the decorative fire
surround and hearth.
This should be achieved using fire cement. Any void surrounding an
inset stove when installed should be filled with fire cement in the interest
of safety and efficacy.
5.8
Adjusting the self leveling feet (if applicable)
Adjustment is as follows:
• Position the stove on the hearth into its final resting place.
• On the rear leg of the stove, loosen the pozi screw, and rotate the
inner ’cam’ shaped leveling foot until this touches the hearth.
• Re-tighten the pozi screw. Check the stove is level with a spirit level.
• Repeat for the other rear leg.
6
Connecting the boiler to your heating circuit
6.1
Safety cooling loop (for Stratford dedicated wood
boilers)
Your stove features three extra connections as shown below. These
should be used if you choose to configure your stove installation to work
with a cooling loop.
Please seek specialist advice when using these connections.
A
suggested configuration is shown in figure 4 on the next page.