Wet Stove Installation Guide
Figure 1: Grate Bars shown seated on their comb outside the stove.
5.3
Fitting the spigot outlet to the stove
With the exception of the Stratford Ecoboiler 7, the flue outlet spigot is
found packed inside the appliance. The hot plate is supplied fitted to the
top opening and is removed by turning clockwise.
Smear a very thin layer of fire cement on the mating faces of the flue
outlet and the hot plate. Fit the outlet to the appliance in the desired
position.
5.4
Connecting the spigot outlet to the flue system
The flue pipe must be fitted inside the outlet spigot as shown in Figure
2 on the following page. Failure to do so could result in the spillage of
condensation running down the flue.
Fire cement should be used to create an airtight seal between the flue
and spigot.
BK555 Rev09