![AR 10012514 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/ar/10012514/10012514_operating-and-service-manual_2962271042.webp)
Model 300T2G8
Table 3-8. *STB?; Response Codes
(The command *STB?; causes the TWTA to send a string containing an operational state code consisting of 2
ASCII characters representing hex digits. The response is in the form
STATUS:
[x][y][eol]
where the hex values
of
[x]
and
[y]
are formed as shown below)
y bit
Meaning
0 (LSB)
Power status; always 1(power on)
1
Standby status; 0 if not in standby, 1 if in standby
2
Operate status; 0 if not in operate, 1 if in operate
3 (MSB)
Fault status; 0 if no fault, 1 if fault exists
x bit
Meaning
4 (LSB)
Mode switch; always 1 (reset)
5
Blank switch; always 1 (off)
6
Blank status; always 0 (off)
7 (MSB)
Not used; always 0
Table 3-9. Catalog of Heater Auto Off Time Delay Codes
Argument Meaning
0
0.5 hour heater auto off time delay
1
1.0 hour heater auto off time delay
2
1.5 hour heater auto off time delay
3
2.0 hour heater auto off time delay
4
2.5 hour heater auto off time delay
5
3.0 hour heater auto off time delay
Command syntax is in this form:
<command mnemonic> <parameter> <carriage return>
where;
<command mnemonic> consists of one of any valid command found in Table 3-3.
<parameter> (as applicable) consists of one ASCII space character followed by a number.
<carriage return> consists of an ASCII carriage return.
All commands are case sensitive.
The system will return parameter values, fault codes, and status codes regardless of whether remote is enabled.
The parameter value is returned as a string of 20 characters or less, consisting of a label,
=
, and a value. For
example, outputting the command RDEF to the TWTA would result in the TWTA sending back the string
Ef=6.03
(assuming the heater voltage is 6.03 volts). Units are usually not returned; see table 3-3 for the units.
24
Rev A
Содержание 10012514
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 16: ......
Страница 24: ......
Страница 46: ...Model 300T2G8 28 Rev A...
Страница 50: ...Model 300T2G8 32 Rev A...
Страница 54: ...Model 300T2G8 36 Rev A...
Страница 55: ...5 3 WIRING DIAGRAMS 20 22520 000 TWT Power Supply 10 1 2 Series A22520 052 Rev A 37...
Страница 56: ...Model 300T2G8 38 Rev A...