Command Function
Units
Response
format
RDTMPPSF
Returns power supply temp (°F)
°F
PSF=[ ]F
RDTMPPSC
Returns power supply temp (°C)
°C
PSC=[ ]C
RDTWTOTF
Returns TWT overtemp warning setpoint (°F)
°F
TWTOTF=[ ]F
STWTOTF
Sets TWT overtemp warning setpoint (°F)
°F
RDTWTOTC
Returns TWT overtemp warning setpoint (°C)
°C
TWTOTC=[ ]C
STWTOTC
Sets TWT overtemp warning setpoint (°C)
°C
RDPSOTF
Returns power supply overtemp warning setpoint (°F)
°F
PSOTF=[ ]F
SPSOTF
Sets p. s. overtemp warning setpoint (°F)
°F
RDPSOTC
Returns p. s. overtemp warning setpoint (°C)
°C
PSOTC=[ ]C
SPSOTC
Sets p. s. overtemp warning setpoint (°C)
°C
RDIWOC
Returns helix overcurrent warning setpoint
mA
IwOC=[ ]
RDLOGIC
Returns logic state code (see Table 3-6)
Sys=[ ]
RDA
Returns gain
%
A=[ ]
SA Sets
gain
%
RDHTDREM
Returns remaining heater time delay
sec.
HTD=[ ]s
RDPOD
Returns forward power out (dBm)
dBm
Po=[ ]dBm
RDPOW
Returns forward power out (W)
watts
Po=[ ]W
RDPRD
Returns reverse power out (dBm)
dBm
Pr=[ ]dBm
RDPRW
Returns reverse power out (W)
watts
Pr=[ ]W
RDPOHID
Returns over forward power warning setpoint (dBm)
dBm
Pohi=[ ]dBm
SPOHID
Sets over forward power warning setpoint (dBm)
dBm
RDPOLOD
Returns under forward power warning setpoint (dBm)
dBm
Polo=[ ]dBm
SPOLOD
Sets under forward power warning setpoint (dBm)
dBm
RDPOHIW
Returns over forward power warning setpoint (W)
watts
Pohi=[ ]W
SPOHIW
Sets over forward power warning setpoint (W)
watts
RDPOLOW
Returns under forward power warning setpoint (W)
watts
Polo=[ ]W
SPOLOW
Sets under forward power warning setpoint (W)
watts
RDPRHID
Returns over reverse power warning setpoint (dB)
dBm
Prhi=[ ]dBm
SPPRHID
Sets over reverse power warning setpoint (dBm)
dBm
RDPRHIW
Returns over reverse power warning setpoint (W)
watts
Prhi=[ ]W
SPRHIW
Sets over reverse power warning setpoint (W)
watts
SCWPUL 1
Sets CW/PULSE mode to CW
SCWPUL 0
Sets CW/PULSE mode to PULSE
RDCWPUL
Returns present PULSE or CW mode
[ ]
SYSTEM:ON;
Emulates pressing the System ON button from System OFF ( Exit
Sleep Mode)
SYSTEM:OFF;
Emulates pressing the Power Save button. (Enter Sleep Mode)
RDHTRAUTOOFF
Returns heater auto off delay
hours
SHTRAUTOOFF
Sets heater auto off delay (see Table 3-9)
*IDN?;
Returns the product model number
[ ]
*STA?;
Returns status string (see Table 3-7)
[ ]
*STB?;
Returns status string (see Table 3-8)
[ ]
Rev A
21
Содержание 10012514
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 16: ......
Страница 24: ......
Страница 46: ...Model 300T2G8 28 Rev A...
Страница 50: ...Model 300T2G8 32 Rev A...
Страница 54: ...Model 300T2G8 36 Rev A...
Страница 55: ...5 3 WIRING DIAGRAMS 20 22520 000 TWT Power Supply 10 1 2 Series A22520 052 Rev A 37...
Страница 56: ...Model 300T2G8 38 Rev A...
Страница 72: ......